8. Maintenance
Recommendations
The user must not attempt to access the detector's internal
parts, except areas described in this manual. If the user does
access these parts, the product guarantee will be
considered null and void and DAITEM shall not be held
responsible for any problems. Touching the detector's
internal parts and/or electronic components can damage the
product. Furthermore, the detector is designed in such a
way that these parts and components do not need to be
accessed for operation or maintenance purposes.
8.2 Changing the battery
• The lithium battery pack must be replaced by the same type of pack with the same technical characteristics
(BatLi31 3 V - 1 Ah).
• We advise you to use the DAITEM BatLi31 pack available in the catalogue in order to guarantee individual
safety and equipment reliability.
• Dispose of the waste lithium power pack in an appropriate recycling bin.
To change the battery:
1. Switch the control panel to installation mode and ask the master user to press:
master code
The detector's configuration is saved when the battery is changed.
2. Open the detector casing (see § on Opening).
3. Unclip the lithium battery pack.
4. Wait 2 min. before replacing the flat lithium battery.
5. Close the detector.
6. Switch the control panel back to user mode. Press:
9. Technical data
Specifications
Built-in magnetic contact
Terminal block for external contact 1
Environment
Power supply
Battery life
Average humidity rate
Radio links
Test button
LED Indicator lamp
Operating temperature
Anti-tamper & protection
Degrees of mechanical protection
Dimensions L x W x H
Weight (with battery)
then
engineer installer code
engineer installer code
Multicontact detector
1
building interior
DAITEM 3.6 V lithium battery
5 years in normal conditions of use
5% to 75% without condensation
at 25°C
TwinBand
®
400/800 MHz
battery and detection
1
-10 °C to +55 °C
• against opening and removal
• against loop cutting
IP 31/IK 04
138 x 26 x 30 mm
70 g
8.1 Battery low indication
The control panel indicates when the multicontact detector's
battery is low.
To check whether there is a problem with the detector
battery, press on the detector's test button.
IMPORTANT: if the test LED indicator
lamp no longer lights up, the lithium
battery should be replaced.
DECLARATION OF CONFORMITY
Manufacturer: Hager Security SAS
Address: F-38926 Crolles Cedex - France
Product type: Multicontact detector
Trade mark: Daitem
We declare under our sole responsibility that the product to which this
declaration relates is compliant with the essential requirements of the
following directives:
• R&TTE Directive: 99/5/EEC
• Low voltage directive: 2006/95/EC
• Directive ROHS: 2002/95/EC
in compliance with the following harmonised European standards:
Products code
EN 300 220-2 V2.3.1
EN 55022 & 55024 (2002)
EN 50130-4 (95) + A1 (98) + A2 (2002)
EN 60950 (2006)
EN 301 489-1 V1.8.1
This product can be used in all EU, EEA Countries
and Switzerland.
Crolles, 02.01.2013
Non-contractual document, may be modified without prior
notice.
Li
"beep, installation
mode"
"beep, date,
time, off"
SH271AX
SH272AX
X
X
X
X
X
Signature:
Patrick Bernard
Director of Research and Development
GB
13
X
X
X
X
X