DSC TL280R Installation Manuals - Page 5
Browse online or download pdf Installation Manuals for Cell Phone DSC TL280R. DSC TL280R 17 pages. Internet alarm communicator - international
Also for DSC TL280R: Installation Manual (16 pages), Installation Manual (16 pages)
General
EN50131-1 Installation Requirements
For EN50131-1 compliant installations, the following programming options shall be set as
described.
Supervision Heartbeat (required for ATS4 and ATS5):
• [851][004] set to 0087h (135s heartbeat).
NOTE: The compatible receiver at ARC location shall have supervision window programmed for
1800s (ATS4) or 180s (ATS 5).
• [851][005] options 1 and 3 shall be enabled
Test transmission (required for ATS3):
• [851] System test options [026] and [027] shall be enabled (FF) for the communication paths
available.
• [851][124] and [125] shall be programmed with time of day for test transmission and 1440 min-
utes (24h) for test transmission cycle
Configuration of communication paths (all ATS classes)
• [300][001] select option 02 for auto routing (this will allow transmission of the events over all
available communication paths in the system)
• [380] enable option 5 (YES) for parallel transmission over all available communication paths
(if redundant configuration is desired)
• [382] enable option 5 (YES) this will enable Alternate communicator
• [384] enable the desired back-up configuration (receiver 2 back-up for receiver 1 or receiver 3
back-up for receiver 1).
Technical Specifications, Ratings and Compatibility
Table 1: Communicator Ratings
Power Supply Ratings
Input Voltage
Current Consumption
Current
Environmental Specifications
Operating Temperature
Humidity
Mechanical Specifications
Board Dimensions (mm)
Weight (grams) with bracket
Table 2: Compatible Receivers, and Panels
Communicator
TL280
NOTE: Enter [*][8][Installer Code][900] at keypad to view the panel version number.
Model
Receiver/
Panel
• Sur-Gard System I Receiver, version 1.13+
• Sur-Gard System II Receiver, version 2.10+
Receiver
• Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
• Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
• Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver)
• HS2016
• HS2032
Panel
• HS2064
• HS2128
Internet Alarm Communicator Installation Guide
Power is supplied from the panel's PC-Link header or a
PCL-422 module in remote cabinet installations. In
remote cabinet installations, the PCL-422 module located
with the communicator is powered by either an HSM2204
or an HSM2300. Refer to the PCL-422 installation
instructions for details.
100mA @ 13.66V
5% ~ 93% relative humidity, non-condensing
Description
2
TL280(R)
10.8-12.5 VDC
-10°C to 55°C
100 × 150 × 15
290