Appendix B: Regulatory Compliance
UL Certification
This equipment is suitable only for use in Class I, Division 2, Groups A, B, C and D OR non-haz-
ardous locations only. Combinations of equipment in your system are subject to investigation by
the local Authority Having Jurisdiction at the time of installation.
Field wiring terminals — use only 105 °C copper (Cu) 14–30 AWG
Terminal tightening torque: 5–7 lb-in (0.5–0.8 Nm)
Maximum surface temperature: 135 °C
Use in Overvoltage Category I Pollution Degree 2 Environment conforming to EN 60664-1
To comply with ATEX directives, the equipment must be installed within an IP54 enclosure
and must be installed with a transient suppressor on the supply that does not exceed
140 % (33.6 V DC) of the nominal rated supply voltage.
®
Anybus
X-gateway
User Manual
WARNING
EXPLOSION HAZARD - SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY
FOR CLASS I, DIVISION 2.
EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE
REPLACING OR WIRING MODULES.
EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN
SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.
EXPLOSION HAZARD- THE USB CONNECTOR IS NOT FOR USE IN HAZARDOUS
LOCATIONS AND FOR TEMPORARY CONNECTION ONLY. DO NOT USE, CONNECT OR
DISCONNECT UNLESS THE AREA IS KNOWN TO BE NONHAZARDOUS. CONNECTION OR
DISCONNECTION IN AN EXPLOSIVE ATMOSPHERE COULD RESULT IN AN EXPLOSION.
INSTALL IN A TOOL LOCKED ENCLOSURE CONSIDERED REPRESENTATIVE OF THE
INTENDED USE.
AVERTISSEMENT
RISQUE D'EXPLOSION – LE REMPLACEMENT DE TOUT COMPOSANTS INVALIDE LA
CERTIFICATION CLASS I, DIVISION 2.
RISQUE D'EXPLOSION – EN ZONE EXPLOSIVE, VEUILLEZ COUPER L'ALIMENTATION
ÉLECTRIQUE AVANT LE REMPLACEMENT OU LE RACCORDEMENT DES MODULES.
RISQUE D'EXPLOSION – NE PAS DÉCONNECTER L'ÉQUIPEMENT TANT QUE
L'ALIMENTATION EST TOUJOURS PRÉSENTE OU QUE LE PRODUIT EST TOUJOURS EN
ZONE EXPLOSIVE ACTIVE.
RISQUE D'EXPLOSION – LE CONNECTEUR USB N'EST PAS FAIT POUR UN USAGE EN
MILIEU EXPLOSIF. NE PAS, BRANCHER ET DEBRANCHER SANS SAVOIR SI LA ZONE N'EST
PAS IDENTIFIEE NON EXPLOSIVE. BRANCHER OU DEBRANCHER EN ZONE EXPLOSIVE
PEUT ENTRAINER UNE EXPLOSION.
INSTALLER DANS UNE ARMOIRE VERROUILLEE VALIDANT L'ACTE VOLONTAIRE
D'UTILISATION.
17 (18)