Anyload DD-KC1 Instruction Manual
the Maximum Capacity and Division. After the screen displays "0", you can begin to
measure the object.
When power-on, press
4.2 Instruction for load cell connection
4.2.1 Connection of the load cell
The connection of the four wire load cell and the indicator:
Connect +EXC with the red wire of the indicator's cable.
Connect –EXC with the black wire of the indicator's cable.
Connect +SIG with the green wire of the indicator's cable.
Connect –SIG with the white wire of the indicator's cable.
The indicator provides driving voltage through +EXC wire and –EXC wire. +SIG
wire and –SIG wire will transmit the change of signal voltage to the indicator.
*To avoid short circuit, please make sure the welding parts of all the wires
covered by the heat shrinking tube.
Figure: Connection of the Load Cell and the indicator
4.2.2 Load cell output sensitivity:
1~2m V/V
4.2.3 Factory parameter setting.
1. Turn off the scale, then hold the three buttons:
same time until the screen displays "------";
2. Press
3. Press
Page 3 of 11
button to turn off the scale.
or
button to go through the menu;
button to enter the display menu.;
,
Anyload-manual-indicator-DD-KC1-en-101
and
at the