Duke RUF 48 Service Manual - Page 7

Browse online or download pdf Service Manual for Refrigerator Duke RUF 48. Duke RUF 48 12 pages. Refrigerated counter
Also for Duke RUF 48: Installation And Operation Manual (8 pages)

Drain Maintenance – Base
Located at the rear of each unit is a drain hose,
which removes the condensation from the
evaporator coil and deposits it into a drain pan
for evaporation (see Figure 3).
Figure 3
Location of Drain hose and Drain Pan
If excessive water accumulates inside the unit,
check to see that the drain hose is connected
from the evaporator housing to the drain pan. If
water accumulates underneath the unit, check
to see that the drain hose is located above the
drain pan.
A level unit is essential for proper drainage. Be
sure to provide a level surface below the unit,
especially if the floor is not level. Keep the drain
pan free from dirt, dust and debris to prevent water
from backing up and overflowing from the drain
pan onto the floor.
Service Manual for Refrigerated Back Bar Model RUF 48

PARTS REPLACEMENT

Thermostat Replacement

General
The thermostat is located inside the cooling
compartment and is accessible through the
doors.
1. Disconnect unit from power source.
2. Remove shelves.
3. Remove shelf support.
4. Remove sheet metal panel.
5. Remove thermostat from back panel.
6. Remove thermostat probe from evaporator
coil.
7. Tag and disconnect thermostat wiring.
8. Remove thermostat from unit.
9. Install replacement thermostat.
NOTE: Do not kink thermostat probe.
NOTE: To ensure proper operation, place 8" of
thermostat probe into evaporator coil.
10. Install thermostat probe in evaporator coil.
11. Using tags, connect thermostat wiring.
12. Install sheet metal panel.
13. Install shelf support.
14. Install shelves.
15. Connect unit to power source and test.
7