Danfoss ECtemp 530 Installation Instructions Manual - Page 7

Browse online or download pdf Installation Instructions Manual for Thermostat Danfoss ECtemp 530. Danfoss ECtemp 530 16 pages.
Also for Danfoss ECtemp 530: Installation Manual (16 pages)

Danfoss ECtemp 530 Installation Instructions Manual
ECtemp 530
▪ Place the floor sensor in a conduit in an appropriate
place where it is not exposed to sunlight or draft
from door openings.
▪ Equally distant and >2cm from two heating cables.
▪ The conduit should be flush with the floor surface -
countersink the conduit if necessary.
▪ Route the conduit to the connection box.
▪ The bending radius of the conduit must be min
50mm.
Installation Guide
Note: A floor sensor enables a more accu-
rate temperature control and is recom-
mended in all floor heating applications
and mandatory under wooden floors to
reduce the risk of over-heating the floor.
7