Danfoss VLT MCD 200 Installation Instructions
MCD USB Module Instructions
4. Configuration
To bring the USB Module on-line:
1. Remove control power and mains supply from the soft starter.
2. Attach the module to the soft starter as illustrated.
3. Connect the module to the PC via a USB cable. The PC should detect the module and the
Hardware Update Wizard will open.
4. Install the supplied USB UART driver to operate the module as follows.
The driver can be found in the USB Comms Drivers folder on the supplied CD. Click on the Browse
button then navigate to the drivers folder and select the appropriate folder for your operating
system.
Click on Ok, then Next. The software will install. If you see a prompt, click Continue Anyway. Once
installation is complete, click Finish.
5. The PC will prompt you to install serial port driver software. Repeat the procedure in
Step 4. You may need to restart your PC once the driver software is installed.
MI.17.C1.02 – VLT
®
is a registered Danfoss trademark
Configuration