AudioCodes Mediant 1000B Configuration Note - Page 10

Browse online or download pdf Configuration Note for Network Router AudioCodes Mediant 1000B. AudioCodes Mediant 1000B 20 pages. Gateway & e-sbc
Also for AudioCodes Mediant 1000B: Quick Manual (2 pages), Quick Setup Manual (8 pages)

AudioCodes Mediant 1000B Configuration Note
2.2

CLI Command Procedure

Once you have established CLI communication, as described in Section 2.1, you need to
run specific CLI commands for restoring defaults. The CLI command procedure depends
on the type of device you are using.
2.2.1
MSBG Series, GW & E-SBC Series, and Mediant 4000
For the MSBG Series, Gateway & E-SBC Series, and Mediant 4000 E-SBC devices, follow
the procedure below.
To restore factory defaults:
1.
At the CLI prompt, type the username (default is "Admin" - case sensitive), and then
press Enter:
# Username: Admin
2.
At the prompt, type the password (default is "Admin" - case sensitive), and then press
Enter:
# Password: Admin
3.
At the prompt, type the following, and then press Enter:
> enable
4.
At the prompt, type the password again, and then press Enter:
# Password: Admin
5.
At the prompt, type the following to reset the device to default settings, and then press
Enter:
# write factory
The CLI commands mentioned in the procedure are shown in the terminal emulation
program (HyperTerminal) below:

Figure 2-1: CLI for Resetting Device to Default (MSBG Devices)

Configuration Note
10
Restoring Factory Defaults
Document #: LTRT-30302