DANIU RTU5024 User Manual - Page 10
Browse online or download pdf User Manual for Gate Opener DANIU RTU5024. DANIU RTU5024 13 pages. Gsm gate opener gsm remote switch
www.daniu-iot.com
6.8 Check GSM signal quality
pwd# CSQ?
Check GSM signal quality. This command is useful to see the GSM network signal level of your GSM
Gate Opener is receiving. After you send the command, you can receive a SMS with signal quality in
range 0 to 31 (if it is 0 we doubt it will ever answer). You should have a signal above 12 to be sure of
being able to open the gate in any condition. Better if above 16. You should add an external GSM
antenna if this is not the case, or eventually even change operator with another that serves your area
better.
6.9 Enable return SMS confirmation when Relay action
pwd#R#
Tips:
if you enable it, when the relay action, close or open, the unit will return a SMS confirmation to
you(The first user number). The return SMS is:
by
xxx. You can disable it by the following command:
confirmation when relay action. This is very useful when you use theRTU5024 to control the
equipments remotely.
To check the settings, you can use the command:
ON
or
Relay action return SMS
6.10 Control the relay ON/OFF by SMS command
pwd# ON #
Return SMS: The relay is ON.
pwd# OFF #
Return SMS: The relay is OFF.
7. Installation
Before installing the control unit, please help to test the system firstly, including power supply,
GSM signal, etc.
7.1 Connecting the Electronic Lock or Electricity equipments
Relay ON! Operated by xxx
pwd#M?
OFF.
- 8 -
or
Relay OFF! Operated
pwd#N#
. Default is no return SMS
It will return:
Relay action return SMS