AudioStak ProSwitch PRSW-4HL-PCB Manual And Installation Manual - Page 17

Browse online or download pdf Manual And Installation Manual for Control Unit AudioStak ProSwitch PRSW-4HL-PCB. AudioStak ProSwitch PRSW-4HL-PCB 20 pages.

AudioStak ProSwitch PRSW-4HL-PCB Manual And Installation Manual
Mute Time
When some components, such as amplifiers, are turned on and off they can produce audible 'pops' and
'thumps' which are undesirable. To eliminate this, the Mute Time function can be used so speakers are
temporarily muted every time a component is turned on or off.
The first DIP switch on the Main Modules (see Figure 1) has two switches for setting Mute Times. When this
function is enabled on a Main Module in a Speaker Group, all Positions on that Board will be turned off
momentarily so the speakers are disconnected. Selectable Mute Times are 0.5 seconds, 1.5 seconds, 3.5
seconds, or none (disabled), as shown in Figure 14. Setting these DIP switches on a Main Module in a
Component Group has no effect.
DISABLED
MUTE TIME:
0.5 SECONDS
1.5 SECONDS
3.5 SECONDS
Figure 14: Main Module DIP Switches for Mute Time
Overview – Mute Time
OFF
OFF
OFF
ON
ON
OFF
ON
ON