Belimo UK24LON Product Information - Page 6

Browse online or download pdf Product Information for Gateway Belimo UK24LON. Belimo UK24LON 16 pages. Gateway mp/lonworks

Belimo UK24LON Product Information
Connecting MFT(2)/MP actuators, Connecting sensors

Connecting MFT(2)/MP actuators

UK24LON
Power
Error
Node
MFT - H
IC-DZ.03
LonTalk
MP-Com.
a
b
0V
24V
AC 24 V
DC 24 V
When rating the power supply
do not forget to include the
MFT(2)/MP actuators that are
also connected.

Connecting sensors

One sensor can be connected to each
MFT(2)/MP actuator. It can be either a pas-
sive resistance-type sensor (e.g. Pt1000,
UK24LON
UK24LON
Power
Power
Error
Error
Node
Node
MFT - H
MFT - H
IC-DZ.03
IC-DZ.03
LonTalk
LonTalk
MP-Com.
MP-Com.
a
a
b
b
0V
0V
24V
24V
AC 24 V
When rating the power
DC 24 V
supply do not forget to include
the MFT(2)/MP actuators that
are also connected.
6
C
B
Made in Switzerland
Address
Test in
Progress
Reg'd
Status
Select
Test
Up
Set
Service
Power
Y
U/MP
0V
24V
n.c.
MP
24 V
-
+
Connect through
!
a safety trans-
former
Ni1000 or NTC), an active sensor (e.g.
with a DC 0...10 V output) or a switching
contact. This provides a simple means
C
C
B
B
Made in Switzerland
Made in Switzerland
Test in
Address
Address
Test in
Reg'd
Reg'd
Status
Status
Progress
Progress
Select
Select
Test
Test
Up
Up
Set
Set
Service
Service
Connecting
passive sensors
Power
Power
Y
Y
U/MP
U/MP
0V
0V
24V
24V
n.c.
n.c.
(Pt1000, Ni1000, NTC)
-
+
Connect through
!
a safety transformer
®
L
W
ON
ORKS
MP
24V
1
2
3
5
1
2
/
/
Y
U
Z
MP
-
-
+
+
MFT(2)/MP actuator
MFT(2)/MP-Antrieb
MFT(2)/MP actuator
MFT(2)/MP-Antrieb
1
2
3
5
1
2
/
/
Y
U
Z
MP
-
-
+
+
MFT(2)/MP actuator
MFT(2)/MP-Antrieb
MFT(2)/MP actuator
MFT(2)/MP-Antrieb
L
W
®
ON
ORKS
Note:
... MFT = Active sensors and switches can be
connected
... MFT2/MP = Active sensors, switches and passive
sensors can be connected
Connecting
active sensors
(permitted input
voltage range 0...32 V)
1
2
3
5
1
/
/
Y
U
Z
MP
-
-
+
MFT(2)/MP-Antrieb
MFT2/MP actuator
MFT(2)/MP actuator
MFT(2)/MP-Antrieb
3
5
1
2
3
5
/
/
/
/
Y
U
Y
U
Z
MP
Z
MP
-
+
MFT(2)/MP actuator
MFT(2)/MP-Antrieb
3
5
1
2
3
5
/
/
/
/
Y
U
Y
U
Z
MP
Z
MP
-
+
MFT(2)/MP actuator
MFT(2)/MP-Antrieb
of digitising the analogue signal from the
sensor through the actuator so that it
can be passed on to L
ON
UK24LON unit.
Connecting
external switches
(e.g. pressure monitors)
MP
24V
∆p
2
3
5
1
2
/
/
Y
U
Z
MP
-
+
+
MFT(2)/MP actuator
MFT(2)/MP-Antrieb
1
2
3
5
/
/
Y
U
Z
MP
-
+
MFT(2)/MP actuator
MFT(2)/MP-Antrieb
1
2
3
5
/
/
Y
U
Z
MP
-
+
MFT(2)/MP actuator
MFT(2)/MP-Antrieb
W
via the
®
ORKS
More actuators
and sensors
(total 8)
3
5
/
/
Y
U
Z
MP