Duratool D01841 Instructions - Page 2

Browse online or download pdf Instructions for Rework stations Duratool D01841. Duratool D01841 3 pages. 240v hot air rework station
Also for Duratool D01841: Quick Manual (4 pages)

Duratool D01841 Instructions
Please read these instructions carefully before use and retain for future reference.
IMPORTANT SAFETY INFORMATION
When using electrical appliances basic safety precautions should always be
followed.
Check that the voltage indicated on the rating plate corresponds with that of the
local network before connecting the appliance to the mains power supply.
Do not operate the appliance with a damaged plug or cord, after a malfunction or
after being dropped or damaged in any way.
If the supply cord is damaged, it must be replaced by a qualified engineer in order
to avoid injury or a hazard.
There are no user-serviceable parts in this product. Refer servicing to qualified
personnel.
The nozzle and accessories of this tool become extremely hot during use. Let
these parts cool down before touching or changing accessories.
Do not expose to rain or moisture.
Do not leave the appliance unattended when it is switched on.
Do not direct the hot airflow towards yourself or others.
Do not use in the presence of an explosive atmosphere.
A fire may result if the appliance is not used with care, therefore be careful when
using the appliance in places where there are combustible materials. Be aware
that heat may be conducted to combustible materials that are out of sight.
This appliance is not intended for use by persons (including children) who are not
mentally able, physically capable, experienced or do not understand the product.
They should be given supervision and instruction in the use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Do not apply heat to the same place for a long time.
Ensure there is sufficient space and ventilation around the appliance to allow the
escape of heat and/or fumes.
Never place the product or part of it in water, or operate if your hands are wet.
Always observe the safety instructions and applicable regulations.
Always place the tool on it's stand when not in use.
Disconnect from the mains supply when not in use.
WHAT'S INCLUDED
Hot air rework station with holder and tool
Pick up wire and holder tool (D03329 only)
4 off various size nozzles
Mains lead
Instruction manual.
OPERATION
Remove the four transit screws on the base of the unit.
Connect the mains lead to the socket on the rear of the station.
De-Soldering IC's
Attach the most suitably sized nozzle for the size of the IC to the tool.
Select the FP pick up wire to suit the type of IC you are about to work on.
2
Connect the mains plug to a socket and switch the power on. The air pump will
operate but the heating element remains off (D03329 model only).
Turn on the power switch and the heating element will start to warm up to the set
temperature. The LED will illuminate while the element is heating (D03329).
On D01841 when power is turned on the display will indicate the current status.
Switch on the fan (D01841) and on either model adjust the air flow as required.
Adjust the temperature to the required setting and wait a few seconds for the
actual temperature to be reached.
Use only one hand to hold the hot air tool and one to hold the pick-up tool.
Place the pick-up wire under the IC pins.
Put the nozzle over the IC, do not touch the IC or it's pins with the nozzle.
When the hot air melts the solder tin on the IC pins, lift the pick-up wire to remove
the IC.
QFP Soldering
Apply solder paste and install the SMD on the PCB.
Pre heat the SMD before heating fully and applying solder.
Wash any flux off after completion.
TEMPERATURE ADJUSTMENT
D03329 model.
Use the rotary control to set the required temperature.
Positions 1-4 is up to 350
o
C
Positions 5-8 is from over 350
o
C to 450
Use the left rotary control to set the air volume as required. For smaller nozzles
use 1-5 and for higher temperatures over 450°C and larger nozzles use 4-7.
D01841 model.
Adjust the temperature by pressing the UP or DOWN buttons below the LCD on
the station front panel.
The lower figure is the required temperature, the upper figure shows the actual tip
temperature.
While the iron is heating up to the required temperature "HEAT ON" displays on
the LCD.
If the difference between the required temperature and that of the iron tip is greater
than 10° "WAIT" displays on the LCD.
To change from °C to °F press "
o
the temperature figure.
Use the rotary control to set the air volume as required. For smaller nozzles use
1-5 and for higher temperatures over 450°C and larger nozzles use 4-7.
o
C.
C /
o
F" button. The display shows °C or °F after