MECHANICAL
Daughter Board Jumper Blocks
for EIA Bias and Termination
Figure 3
DC-Coupled
EIA-485 ROTARY DATA RATE SWITCH
Although the switch in Figure 5 displays stops for only 3 data
rates, every rate in Table 1 has a stop. Count the clicks to
determine the five unlabelled rates. At one stop clockwise past
the 5.00 position, you get 10 Mbps. The next clockwise stop
selects the 78 kbps rate — then 156 kbps, 312 kbps and 625
kbps in turn — until the 1.25 (Mbps) label is reached.
Figure 2 — AI-USB Dimensions
Figure 4
AC-Coupled
TD030500-0IB
3
Figure 5 — EIA-485
Data Rate Switch