DURAVIT Utronic 0830370092 Mounting Instructions - Page 11

Browse online or download pdf Mounting Instructions for Plumbing Product DURAVIT Utronic 0830370092. DURAVIT Utronic 0830370092 16 pages. Infrared sensor urinal

DURAVIT Utronic 0830370092 Mounting Instructions
# 1002960000
Electronic Unit
4
Remove the electronic unit.
Replacing the electronic unit
1
Using Allen wrench (4 mm) unscrew
the bottom portion of the electronic
unit.
5
Attach electrical connection (new
electronic unit).
2
Slide the old electronic unit forward.
1
2
0,6 Nm
6
Using Allen wrench (4 mm) tighten
the electronic unit.
3
Detach electrical connection.
7
Remove film from the sensor and
refer to page 8 for starting instruc-
tions.
MAL_51173/14.06.8