DURAVIT Utronic 0830370092 Mounting Instructions - Page 13

Browse online or download pdf Mounting Instructions for Plumbing Product DURAVIT Utronic 0830370092. DURAVIT Utronic 0830370092 16 pages. Infrared sensor urinal

DURAVIT Utronic 0830370092 Mounting Instructions

Removing errors

ERROR
No flush but click of
magnetic valve
No flush, no click of
magnetic valve
Flush without use
Permanent flush
SOURCE OF ERROR
Closed stop valve
Blocked dirt trap
Battery empty
Broken magnetic valve
Empty battery
Electronical interruption
Electronic unit out of order
Broken magnetic valve
Wrong sensor focus
Broken electronic unit
polluted magnetic valve
Broken magnetic valve
REMOVE ERROR
Open stop valve
Clean dirt trap
Replace battery
Replace magnetic valve
Replace battery
Check electronical connections
Replace electronic unit
Replace magnetic valve
Restart electronic unit*
Replace electronic unit
Clean membrane of magnetic
valve or replace magnetic valve
Replace magnetic valve
*RESTART ELECTRONIC UNIT
Cover sensor with black tape
Unscrew metal cover
Unplug battery
Plug battery
Screw on metal cover
Remove black tape from sensor
SEE PAGE
ARTICLE-CODE
13
9
1002130000
10 - 11
1002110000
9
1002130000
12
1002960000
10 - 11
1002110000
see explanation* below
12
1002960000
10 - 11
1002110000
10 - 11
1002110000
MAL_51173/14.06.8
13