Abusemark LCD Quick Start Manual - Page 3
Browse online or download pdf Quick Start Manual for Adapter Abusemark LCD. Abusemark LCD 5 pages.
Also for Abusemark LCD: Manual (5 pages)
AbuseMarK LCD Adapter Manual
Improper connection examples
Left image: Cable not aligned correctly, not fully inserted. Powering up like this will likely burn the panel.
Right image: Cable inserted circuit (gold) side down, this is incorrect.
External Power 5V source
When arranging many panels in array, its easier to source a single 5V connector for all panels and avoid
USB cable mess.
A standard 2.54mm (0.1") pin header connection is provided for this purpose. User can solder in pin
header or wires directly. Left‐side is positive (+) and right side is negative (‐). The following 3 pads (tx,
GND, rx) are NOT related to power and 5V must not be connected to them at any time. These pads are
for emergency firmware recovery or debugging.
12/17/2013