Elsner 70513 Installation And Adjustment - Page 5

Browse online or download pdf Installation And Adjustment for Controller Elsner 70513. Elsner 70513 20 pages. Multifunctional actuators

Elsner 70513 Installation And Adjustment
1.

Description

Actuators KNX S1R-UP with integrated façade control have a multifunctional output
which can connect to either a drive with Up/Down control (blinds, awnings, shutters,
windows) or two switchable devices (On/Off for light and ventilation). Because the out-
put is designed to be free of potential, other systems can also be controlled, e.g. via the
manual switch input on a motor control unit.
Automation can be specified externally or internally. Internally, there are numerous op-
tions available for blocking, locking (e.g. master-slave) and priority definitions (e.g.
manual-automatic). Scenes can be saved and called up via the bus (scene control with
16 scenes per drive).
The KNX S1R-B4-UP and KNX S1R-BA2-UP models are equipped with inputs which
are used as bus inputs (buttons, alarms, etc.) or for T-NTC temperature sensors. The
KNX S1R-UP model does not have any analogue/digital inputs.
Functions:
Free of potential multifunctional output for a 230 V drive (shading,
windows) or connection of two switchable devices (light, fan)
Relays switch with low wear near the zero-voltage transition
Inputs for binary contact or temperature sensor (not on KNX S1R-UP)
Automatic runtime measurement of the drives for positioning (incl. fault
reporting object)
Position feedback (movement position, also slat position for shutters)
Position storage (movement position) via 1-bit object (storage and call-up
e.g. via buttons)
Parameters for taking drive and mechanics downtimes into account
Control via internal or external automation functions
Integrated shade control with slat adjustment for shutters based on the
position of the sun
Scene control for movement position with 16 scenes per drive (also slat
position for shutters)
Mutual locking of two drives using zero position sensors prevents collisions
e.g. of shade and window (master–slave)
Blocking objects and alarm reports have different priorities, so safety
functions always take precedence (e.g. wind block)
Manual or automatic priority setting via time or communication object
4 temperature switching outputs in the application program with
adjustable threshold values (presetting the parameters or communication
object)
Brief time limit (movement command blocked) and 2 movement limits
Configuration is made using the KNX software ETS 5. The product file can be down-
loaded from the ETS online catalogue and the Elsner Elektronik website on www.els-
ner-elektronik.de in the "Service" menu.
Actuators KNX S1R-UP • Version: 27.05.2020 • from software version 4.00, ETS programme version 4.00 •
3
Technical changes and errors excepted.
Description