Dataprobe iBoot Instruction Manual - Page 9

Browse online or download pdf Instruction Manual for Switch Dataprobe iBoot. Dataprobe iBoot 16 pages. Web enabled remote power control
Also for Dataprobe iBoot: Manual (20 pages)

Dataprobe iBoot Instruction Manual
iBoot
Page 9

iBoot Configuration

Setting I/P Address
iBoot comes with factory installed IP address 192.168.1.254. In
most cases this will need to be changed.
Consult your Network Administrator to determine the appropriate
IP address. The IP address can be set either using ARP, or via
a web browser. The iBoot does not support DHCP.
Setting the IP address using Web Browser
Setting the IP address using the Web Browser requires
rebooting the iBoot. Do not use this procedure from a
remote location.
To set the IP address using a Web Browser, connect the
10/100Base-T connection to your local ethernet network and
apply power to iBoot.
Open your browser and access iBoot by entering the default
(192.168.1.254) or current IP address into your browser's
Address window. Enter the password (the factory default is
PASS). Click on Setup and enter the IP address, Subnet Mask
and Gateway address for your network. Click on Apply.
Disconnect the Power Input to the iBoot. When you reconnect
power, the new IP address will be installed. See Web Browser
Control for more details and screenshots.
Changes to the Subnet Mask and Gateway occur as soon as the
apply button is pressed and do not require power cycling iBoot.
Setting the IP address using ARP
The computer used to set the IP address must be on the same
local network segment as the iBoot. ARP does not work across
routed or switched networks.
To set the IP address using ARP, the hardware (MAC) address
must be known. This address is located on the bottom of the
unit. The syntax for the MAC address is: nn-nn-nn-nn-nn-nn