Dux Platinum 3000 Series Product Manual - Page 6
Browse online or download pdf Product Manual for Power Tool Dux Platinum 3000 Series. Dux Platinum 3000 Series 20 pages. Pressure feed
Operation Guide
Connect a clean air supply
Connect a clean, dry air supply to the Platinum
Pressure Feed via the 1/4" NPS air inlet fitting.
Note that many compressed air systems may
be contaminated with particulate, compressor
oil and/or water. These materials can foul the
inside of the spray gun, leading to gun malfunc-
tion or defects in your final finish. If you have
any question regarding the quality of your air
supply, please contact DUX for recommenda-
tions on proper air filter/dryer equipment.
Set Initial Air Pressure
As a starting point, adjust the air regulator to
achieve approximately 5 psi at the base of the
spray gun when the gun is triggered. Keep in
mind that hoses cause a drop in air pressure, so
it may be necessary to set the pressure at your
regulator well above 5 psi to maintain 5 psi at
the base of the gun. To ensure you begin with
the proper pressure, it is a good idea to install a
separate gauge (or a small regulator) at the base
of the gun.
Air Pressure:
Wall / Pressure Pot Regulator
Figure 3: Pressure Gauge Installation
For customer service call 888.389.2732
5 Psi
Here
PLATINUM PRESSURE FEED
Due to DUX's the patented Advanced Laminar
Air-flow design, a setting of 5 psi at the base of
the gun will result in approximately 5 psi at the
air cap—which is sufficient to atomize many
coatings at a moderate fluid flow rate.
Later, when test spraying the gun, you will adjust
the air pressure up or down depending upon
atomization quality with your particular coating.
Be sure to make a note of the triggered pressure
reading at your regulator at that time. This will
allow you to easily return to the proper gun set-
tings in the future. Also, remember to adjust your
settings if you change hoses, since pressure
drop will vary depending upon the length and
diameter on the hose used.
Note Unlike traditional HVLP and Conven-
tional Air Spray guns, very little air pressure is
lost inside the DUX gun. It is not necessary
to begin with high pressure (30+ psi) at the
gun inlet.
Connect a filtered fluid supply
A clean fluid supply is also required for reliable
gun performance and a high quality finish. For-
eign objects (typically dried chunks of coating)
will cause surface defects and may foul the fluid
tip and needle—leading to leaks.
We highly recommend the installation of a high
quality fluid filter as close to the gun as possible.
The size and type of filter will depend upon your
coating and application. If you have any ques-
tions regarding the quality of your fluid supply,
please contact DUX for recommendations on
proper fluid filtration equipment.
Connect your properly filtered fluid supply to the
DUX Platinum Pressure Feed via the 3/8" NPS
fluid inlet fitting at the base of the gun as shown
in Figure 2.
Set Initial Fluid Pressure
Three elements control the fluid flow rate
through the DUX gun:
1) Fluid Inlet Pressure
2) Fluid Tip Size
3) Fluid Micrometer Settings
Page 6