Afag IRG 1-S Translation Of Operating And Installation Instructions - Page 13

Browse online or download pdf Translation Of Operating And Installation Instructions for Controller Afag IRG 1-S. Afag IRG 1-S 14 pages.

5.2 Troubleshooting and fault repair

Table 2: Troubleshooting and fault repair
Fault:
Appliance not working
Conveyor not working
Conveyor vibrates too much, mag-
net knocking (noises)
Magnet heats up

6 Accessories

6.1 Fixture

Table 3: Order data
Type
Fixture
R02.1
Check the mains voltage, check the fuses and
replace if necessary.
Is the controller input set correctly, are the
jumpers correct?
Check whether the right oscillation frequency
has been set, where necessary alter the set-
ting.
Check the mains frequency (50/60 Hz). The
oscillation frequency and the mains voltage
must conform to one another.
U
trimmer setting too low, set U
max
Incorrect oscillation frequency setting. CAU-
TION! Magnet may have been destroyed by
overheating, or mechanically damaged by
knocking against something.
U
trimmer setting too high, reset U
max
necessary.
Incorrect mains voltage for magnet, check.
Incorrect oscillation frequency set, reset if
necessary.
Designation
for 1 IRG
for 2 IRG
for 1 IRG extended
for 2 IRG extended
04/03/2020
Fault repair
.
max
Order number
50450178
50450179
50450145
50450147
if
max
Page 13