Maintenance

1. Normal cleaning should be all that is necessary. Make sure to clean the radiant heat tubes with the scraper rod and wrench handle every day.
This is a 30 second procedure.
One time a year the Lower Combustion motor should be removed and cleaned. The blades will have buildup on them from regular burning. This
buildup needs to be removed and cleaned by a professional and the motor re-installed, making sure all nut fasteners and lock washers are used for
re-install and tightened down securely. Do not over-tighten the nuts. If the gasket is damaged, it should be replaced to prevent air leaks.
With the combustion motor removed, inspect your chimney pipe inspected for debris, and have it cleaned by a professional at this time if needed.
When it is re-installed make sure that all connections are re-sealed and secure.
BACK - EXPLODED ISO VIEW
5091-147
DAMPER - EXPLODED ISO VIEW
5091-909S
Washer Lock .250
Washer Flat .250
Washer Flat .250
Washer Lock .250
NUT HEX .250-20
5091-912
Washer Flat .250
Washer Lock .250
NUT HEX .250-20
5091-171
socket head cap screw
Washer Flat .190
Washer Lock .190
5091-148
5091-157
NUT HEX .250-20
5091-154
CR-RHMS .25-20 x .50
CR-PHMS .138-32 x .25
5091-216
Washer Flat .190
5091-155