Vertical Install
Always follow standard Pellet Pipe Install Guidelines.
A 509-1 Optimum Elbow (Part # 5091-219) will NEED to be attached and sealed to the 3"
round exhaust motor fitting with High-Temp RTV sealant and 3 self-drilling / tapping screws.
Attaching the 509-1 Optimum Elbow will transition your exhaust to the horizontal position.
The exhaust elbow can be attached to a 3" to 4" or 3" to 3" Exhaust cleanout "T" Exhaust
Pipe for your vertical exhaust termination, or to an appliance adapter and pellet pipe to go
out the wall horizontally. It is recommended to put a minimum of 3ft rise above the
elevation of the motor after going through a sidewall for draft in case of a power outage.
See Pictures Below.
5091-912
5091-916
5091-219
5091-915
T EXHAUST PIPE
CLEAN OUT CAP
VERTICAL VENT
EXPLODED
VERTICAL VENT
BACK COVERS REMOVED