Pulse Width modulation
Pulse Width Modulation is a method of transmitting information on a series of pulses, changing the
frequency, rather than a continuously varying analog signal. It will allow you to control the amperage going
into the generator in a very easy way. This ability keeps the cell running at cool operating temperatures and
prolongs the life of the cell while increasing the HHO output
Efficiency: HHO generators will run cooler than standard linear power amps, requiring substantially less heat
sink mass;
Amperage control: the control of the amperage going into the generator will be very easy to control. The
ability to control the amperage keeps the cell running at cool operating temperatures and prolongs the life of
the cell while increasing the HHO output.
Main Features of the CCPWM60A
NEW TECHNOLOGY: The CCPWM60A (Constant Current Pulse Width Modulator) will allow you to have always
the same amperage and HHO production regardless the electrolyte concentration, water temperature or
water levels. The CCPWM is the best solution for the professional market because there will be no possibility
of error. We can put more or less electrolyte and the amperage and HHO production will always be the same.
The CCPWM60A is also designed for making the automatic power supply of the HHO System without the need
for relays or picking up the signal from the alternator/ignition key, making the system safer to use and easier
to install. In general the new CCPWM60A will work based on the voltage of the car/truck:
- Engine is stoped – voltage in car/truck is 12V or 24V – PWM is not working;
- Engine is working – voltage in car/truck is 13,8V or 27,6V – PWM is working.
The CCPWM60A autodetect when the car engine is running and automatically switches ON the HHO System,
without any additional requirements. The device will automatically power OFF when the car engine is turned
OFF or not running.
The CCPWM is also capable to control a water level sensor inserted in the water tank turning the system OFF
when the level drops from a certain point.
Important: This product is intended for use on an automobile/truck with 12/24V
battery operation only. Working this devise with an independent power supplies
may result in malfunction and/or damage the devise.