Electric Connections

1. Make sure your engine is not running during installation;
2. Mount the product as near of the battery as possible (maximum 3 meters), providing that it is well
fixed. Please do not mount it over the battery;
3. Connect the black cable to the negative terminal of the battery;
4. Connect the red cable to the positive terminal of the battery;
5. Connect the blue cable to the negative coming from the HHO Cell;
6. Only use 4 mm section cable in your installation. Use the Yellow Butt Connectors.
Please refer to the illustration below for typical configuration of the electrical connections of the CCPWM30A: