HHO Plus CCPWM60A Kurulum Kılavuzu - Sayfa 6

Otomobil Aksesuarları HHO Plus CCPWM60A için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. HHO Plus CCPWM60A 11 sayfaları. Hho hydrogen on demand dual fuel generator systems
Ayrıca HHO Plus CCPWM60A için: Kurulum Kılavuzu (12 sayfalar), Kurulum Kılavuzu (10 sayfalar), Kurulum Kılavuzu (10 sayfalar)

HHO Plus CCPWM60A Kurulum Kılavuzu

Electric Connections

1. Make sure your engine is not running during installation;
2. Mount the product as near of the battery as possible (maximum 3 meters), providing that it is well
fixed. Please do not mount it over the battery;
3. Connect the black cable to the negative terminal of the battery;
4. Connect the red cable to the positive terminal of the battery;
5. Connect the blue cable to the negative coming from the HHO Cell;
6. Only use 4 mm section cable in your installation. Use the Yellow Butt Connectors.
Please refer to the illustration below for typical configuration of the electrical connections of the CCPWM30A:
CCPWM60A – Installation Manual
6