Hidro-Water XENA 10.1 User& Installer's Manual - Page 9

Browse online or download pdf User& Installer's Manual for Water Filtration Systems Hidro-Water XENA 10.1. Hidro-Water XENA 10.1 13 pages.

7.- FAULTS, PROBABLE CAUSES AND POSSIBLE SOLUTIONS

ID
SYMPTOM
PROBABLE CAUSE
No water supply.
Brass ball valve at entrance
fully/partially closed.
Insufficient supply pressure.
Flow restrictor obstructed.
Drain obstructed.
Excessive waste.
Zero/low
1
production
Cartridges obstructed.
Membrane saturated.
No power supply.
Pump in poor condition.
Antileak system activated
The membrane hasn't been fitted. Fit membrane.
Damaged membrane O-rings.
Excessive
Damaged membrane housing.
production
2
and/or
Membrane damaged.
elevated TDS
Badly connected tubes.
Damaged shut off valve.
Bitter or
Water with very low salinity level.
3
acidic taste
MA-EN-OSMOSIS XENA10.1-RO-0220-22-FLC-21-V01.0
16
SOLUTION
Wait until the water supply has
been restored.
Open the entrance valve fully.
Check mains pressure. If it is lower than
2.5 bars, then you must install a pump
and its respective switches.
Replace flow restrictor.
Check if the drain line is blocked. If so,
unblock it.
Check the flow in the flow restrictor,
if excessive, replace it.
Replace cartridges.
Replace membrane.
Check the property's power supply or socket.
Check voltage at transformers output.
If there isn't any, replace it.
Check that the pump increase pressure at the
membrane housing inlet. If it doesn't, change it.
Check if the antileak system has activated
itself. If so, detect the leak, fix it, replace
the absorbent material and lower the arm.
Replace the O-rings on the membrane.
Replace the membrane housing.
Replace the membrane.
Wire the connection between the wastage
and the permeate properly.
Replace shut off valve.
Fit a mineralizing postfilter.
ID
SYMPTOM
PROBABLE CAUSE
Plastic or
4
Worn postfilter.
synthetic taste
Unpleasant
Contamination.
5
taste and smell
Air in the system.
White particles
6
in the water
Excessive inlet
pressure.
Shut off valve
deteriorated.
The osmosis
Non-return
system doesn't
valve deteriorated.
7
stop throwing
water away
Excessive inlet
pressure.
Non-return
valve deteriorated.
The osmosis
Excessive
system starts up
sporadically
inlet pressure.
8
without water
consumption
Leak in some point
of the system
and/or faucet.
Very little inlet pressure,
less than 1 bar.
The osmosis
Minimum pressure
9
system stops and
switch in bad condition.
starts.
Deteriorated non-return
valve.
MA-EN-OSMOSIS XENA10.1-RO-0220-22-FLC-21-V01.0
SOLUTION
Replace postfilter.
Change the filters, membrane, postfilter
and sanitise.
Wait for the air to pass as there's no urgent
problem.
Check the mains water pressure, if it is greater
than 4 bars it will be necessary to fit a pressure
regulator at the inlet to the osmosis system.
Replace shut off valve.
Replace non-return valve.
Check the mains water pressure, if it is greater
than 4 bars it will be necessary to fit a pressure
regulator at the inlet to the osmosis system.
Replace the non-return valve.
Check the mains water pressure, if it is greater
than 4 bars it will be necessary to fit a pressure
regulator at the inlet to the osmosis system.
Repair the leak and/or replace faucet.
Bypass the minimum pressure switch (Danger
that the pump could work without water and break.
Replace the minimum pressure switch.
Replace the non-return valve.
17