ADEMCO Ademco VISTA-40 Installation Supplement Manual - Page 11

Browse online or download pdf Installation Supplement Manual for Control Panel ADEMCO Ademco VISTA-40. ADEMCO Ademco VISTA-40 16 pages. E2 zone programming

ADEMCO Ademco VISTA-40 Installation Supplement Manual
6HULHV7UDQVPLWWHU,QSXW/RRS,GHQWLIL.DWLRQ
All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of
the input loops requires its own programming zone (e.g., a 5804's four inputs require four programming zones).
Transmitter inputs entered as:
"RF" (Supervised RF) Type send periodic check-in signals, as well as fault, restore and low battery signals. The
transmitter must remain within the receiver's range.
"UR" (Unsupervised RF) Type send all the signals that the "RF" Type does, but the control does not supervise
the check-in signals. The transmitter may, therefore, be carried off-premises.
"BR" (Unsupervised Button RF) Type only send fault signals. They do not send restore or check-in signals.
They will indicate a low battery condition when tested or activated normally. The transmitter may be carried off-
premises.
LOOP 3
ENROLL AS "BR"
ENROLL AS "RF"
ENROLL AS "RF"
PROGRAM HOUSE ID
Note: For information on any transmitter not shown above, refer to the instructions accompanying that transmitter for
details regarding loop numbers, etc.
UL NOTE:
The following transmitters are not intended for use in UL installations:
5802MN, 5802MN2, 5804, 5804BD, 5814, 5816TEMP, 5819, 5819WHS/BRS, 5827BD, and 5850.
LOOP 3
LOOP 2
LOOP 1
LOOP 4
YOU MUST
ENROLL THIS
BUTTON
ENROLL AS "UR" OR "RF"
5 8 0 1
ENROLL AS "UR" OR "RF"
YOU MUST
LOOP 2
ENROLL THIS
BUTTON
YOU MUST
LOOP 4
ENROLL THIS
BUTTON
LOOP 4
LOOP 1
• •
• • •
• •
• •
SET
• •
HOUSE
CODE
5 8 0 4 B D
LOOP
2
(REED)
LOOP 1
(TERMINALS)
ALTERNATE
5 8 1 6
POSITION
FOR LOOP2
LOOP
2
LOOP
(REED)
1
5 8 1 8
(TERMINALS)
LOOP 3
(TERMINALS)
5 8 1 9
ENROLL AS "RF"
LOOP
(SOUND)
5 8 4 9
5 8 2 7 B D
ENROLL AS "RF"
LOOP
LOOP
1
1
5 8 0 2 M N
ENROLL AS "UR" OR "RF"
LOOP 3
LOOP 2
LOOP 1
5806/5807/5808/5808LST
ENROLL AS "RF"
LOOP
1
5809
ENROLL AS "RF"
5 8 0 4
ENROLL
AS "BR"
LOOP
2
(REED)
LOOP 1
LOOP 1
(TERMINALS)
(TERMINALS)
5 8 1 6 M N
5 8 1 6 T E M P
ENROLL AS "RF"
ENROLL AS "RF"
LOOP
2
(REED)
LOOP 1
(INTERNAL
LOOP 1
SHOCK
LOOP 3
SENSOR)
(TERMINALS)
5 8 1 9 S ( W H S & B R S )
ENROLL AS "RF"
1
(Green)
(Red)
(Yellow)
5 8 5 0 ( G B D )
ENROLL AS "RF"
11
5 8 0 2 M N 2
LOOP
1
LOOP1
REED
SWITCH
5814
ENROLL AS "RF"
LOOP
1
(PRIMARY)
2
(AUX. CENTER)
3
(AUX. RIGHT)
5 8 1 7
ENROLL AS "RF"
5827
SET HOUSE ID
LOOP
1
(MOTION)
5 8 9 0 / 5 8 9 0 P I
ENROLL AS "RF"