Autonics krn100 series Instruction Manual - Page 2
Browse online or download pdf Instruction Manual for Measuring Instruments Autonics krn100 series. Autonics krn100 series 2 pages. 100 mm hybrid recorder
Also for Autonics krn100 series: Instruction Manual (2 pages), Product Manual (3 pages), Manual (17 pages)
QUICK MENU
QUICK MENU consists of usually used parameters for quickly parameter setting.
1) Parameters of QUICK MENU
Page
Parameter
Description
CH
Select channel for the QUICK MENU[1] setting.
TYPE
Input type
QUICK
DOT
Decimal point
MENU [1]
UNIT
Display/Temperature unit [INPUT SETUP]-[Display/Temp Unit]
PEN COLOR
Pen color
CH
Select channel for the QUICK MENU[2] setting.
Low-limit input value or
LOW RANGE
graph scale value
QUICK
High-limit input value or
MENU [2]
HIGH RANGE
graph scale value
LOW SCALE
Low-limit scale value
HIGH SCALE High-limit scale value
PRINT MODE Record mode
PRINT SPEED Standard record speed
QUICK
PRINT MEMO Digital memo period
MENU [3]
BACK LIGHT
LCD backlight
LCD ON/OFF LCD backlight On/Off
USB REC
Memory save
USB COPY
Call USB COPY window
QUICK
MENU [4]
UPGRADE
Call upgrade window
CANCEL
Cancel the settings
SAVE
Save the setting of QUICK MENU[1] to [4].
※Refer to "KRN100 user manual".
Parameters
RUN mode
※ Dot parameters may or may not appear, depending on the other parameter setting.
3 sec
INPUT SETUP
ALARM SETUP
(input setting)
(alarm setting)
Select UI Card
Select UI Channel
(universal input card
(universal input
select )
select)
Input Set Copy
Alarm Set Copy
(input parameter
(copy alarm
copy)
parameter)
LCD/Paper Record
Alarm
type
(display and record
(alarm operation
measuring value)
mode)
Alarm
Ref Channel
Pen Color
(alarm
reference
(record color)
channel)
Record Zone
Alarm
Option
(record zone)
(alarm
option)
Tag Name
Alarm
Value
(channel name)
(alarm
SV)
Input Type
Alarm
Hysteresis
(input
(alarm
hysteresis)
specifications)
Alarm
ON/OFF Delay
OK,
Range/Scale Point
(alarm
output ON/
Cancel
(decimal point)
OFF delay time)
Alarm
Alarm No
Display/Temp Unit
(alarm
output
(display/temp. unit)
alarm number)
High/Low Range
Selection Alarm Card
& Graph Scale
(Alarm output card
(high/low input value
select)
and graph scale)
Low Scale/
Alarm-
Status
High Scale
(relay and transistor
(high/low scale value)
output method
Special Func
(special function)
Two Unit
(display vacuum,
static pressure)
Ref Channel
(reference channel)
Input Bias
(error correction)
Span
(gradient adjustment)
Record Method
(data storage method)
Filter Type
(input digital filter)
Filter Counter
(number of digital
filters)
Burnout Action
(display setting for
break)
Operation
Trend graph
Screen
→ Bar graph
display
→ Digital number
QUICK
Usually used
MENU
parameters of
parameter setting group
are reorganize as
QUICK MENU.
Each parameter setting
Parameter
is linked.
setting
group
2) QUICK MENU Setting
①
Linked parameters
ᆞE.g.) In case of CH1, recording as input type=TC-U, low-limit input value=300, standrad record speed= 240mm/h
[INPUT SETUP]-[Input Type]
①
[INPUT SETUP]-[Range/Scale Point]
[INPUT SETUP]-[Pen Color]
[INPUT SETUP]-[Low Range] or
[INPUT SETUP]-[Low Graph Scale]
[INPUT SETUP]-[High Range] or
[INPUT SETUP]-[High Graph Scale]
[INPUT SETUP]-[Low Scale]
[INPUT SETUP]-[High Scale]
[RECORD SETUP]-[Record Mode]
[RECORD SETUP]-[Standard Speed]
④
[RECORD SETUP]-[Memo Period]
[SYSTEM SETUP]-[Backlight]
[SYSTEM SETUP]-[Backlight On/Off]
[FILE/MEMORY SETUP]-
[USB LogData Save]
[FILE/MEMORY SETUP]-
[USB Memory Copy/Move]
[USER/INFORMATION SETUP]-
[Firmware Upgrade]
DIGITAL INPUT
COMMUNICATION
SETUP
SETUP
(digital input setting)
(com. setting)
Select DI Card
Modbus Address
(digital input card
(com. address)
select )
DI-
Type
RS485 Port
(digital input
(RS485 com. use)
select)
DI-
Reset No
Baud Rate
(reset alarm number)
(com. speed)
DI-
Status
Parity Bit
(operation status)
(com. parity bit)
Stop Bit
(com. stop bit)
Termination Set
(terminating
resistance)
Response Wait Time
(com. response
waiting time)
Protocol
(com. protocol)
RS485 Com/Write
(RS485 com. write)
Ethernet Port
(Ethernet com. use)
IP Address
(IP address)
Subnet Mask
(subnet mask)
Default Gateway
(default gateway)
Ethernet Com Write
(Ethernet com.
write)
USB Device Port
(USB com. use )
USB Com Write
(USB com. write)
Start/Stop
recording
Parameter
setting
information
output
3 sec
RUN mode
Manual feed
(when stop
recording)
3 sec
Digital memo
3 sec
3 sec
②
Press the
key once in RUN mode and it
enters to QUICK MENU.
QUICK MENU consists of usually used param-
eters for quickly parameter setting.
②
Press the
key in RUN mode to enter
QUICK MENU.
⑤
Press the NEXT (
) key once and it moves
to QUICK MENU [3]. Press the SET (
) key
and set standard record speed [PRINT SPEED]
as 240mm/h.
RECORD SETUP
SYSTEM SETUP
(record setting)
(system setting)
Record Mode
Device Name
(record mode)
(device name)
Digital Print type
(1 line record CH during
numeric recording)
Standard Speed
(standard record
speed)
Option Speed
Summer Time
(option record
(summer time)
speed)
Memo Period
Summer Time Period
(digital memo cycle)
(summer time period)
Divide Zone
Reservation Type
(record zone
(reservation record)
division)
Standard Period
Reservation Period
(standard record
(reservation record
cycle)
Option Period
Reservation Time
(option record
(reservation record
cycle)
Listing Language
Alarm Sound
(language for list
(alarm sound)
printing)
Alarm Speed
Sampling Rate
(alarm record
(sampling period)
speed)
Power On Status
(record status when
(save cycle)
power ON)
Run Status
(list printing at start
(LCD backlight
recording)
Baklight On/Off
List Out Option
(LCD backlight ON
(list record option)
Zone Dot Line Distance
(dot line for zone
division)
CH Print Distance
(record interval for
each channel graph
Start Line Print
(start line when
starting record)
Range Print Time
(input range record
period)
Major Products
Photoelectric Sensors
Fiber Optic Sensors
Door Sensors
Door Side Sensors
Area Sensors
Proximity Sensors
Special
Pressure Sensors
function for
Rotary Encoders
record
Connectors/Sockets
Switching Mode Power Supplies
Control Switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper Motors/Drivers/Motion Controllers
Graphic/Logic Panels
Field Network Devices
Laser Marking System(Fiber, CO₂, Nd:YAG)
Laser Welding/Cutting System
③
Set the keys following the each parameter. Press
the NEXT (
) key and it moves to next page.
E.g.) When changing the temperature unit (℃→℉)
of CH1, press the SET (
) key.
③
Press the SET (
) key at QUICK MENU [1]
and below screen is displayed. Set input type
[TYPE] as TC-U by pressing SET (
)
,
keys and press the
key.
Press the NEXT (
) key once and it moves
to QUICK MENU [4]. Press the SAVE (
)
key to save the settings of QUICK MENU [1] to
[4] and it returns to RUN mode.
FILE/MEMORY
SETUP
(file/memory setting)
Load Set File
(parameter setting
file open)
Save Set File
Date/Time
(parameter setting
(date/time)
file save)
Date Type
Memory Status
(date type)
(memory capacity)
Memory Clear
(memory delete)
USB LogData Save
(USB save function)
Memory Save Option
(memory save
option)
USB Memory
Copy/Move
period)
(data move/copy)
time)
Log Speed
Backlight
brightness)
method)
Temperature Controllers
Recorders
Temperature/Humidity Transducers
Indicators
SSRs/Power Controllers
Converters
Counters
Controllers
Timers
Panel Meters
Tachometer/Pulse(Rate) Meters
Display Units
Sensor Controllers
After completing the setting, press the SAVE
(
) key at QUICK MENU[4] and save the
settings. It returns to RUN mode.
Press the NEXT (
) key once and it moves
to QUICK MENU [2]. Press the SET (
) key
using
keys to set
,
,
,
low-limit input range [LOW RANGE] as 300 and
press the
key.
USER/INFORMATION
RECORD BACKUP
SETUP
DATA
(user/info. setting)
(backup data record setting)
Record Backup
Password
(backup data
(password mode)
record)
Login Admin
Backup Data List
(admin. log in)
(backup data list)
Change Admin
Start Date and Time
Password
(start time for data save)
(password change by admin.)
User Lock
End Date and Time
(user authority
(end time for data save)
change)
Backup Print Mode
Information
(backup data print
(system info. check)
mode)
Selection Print Mode
Firmware Upgrade
(backup data recording
(firmware upgrade)
mode setting)
Thyristor Units
Pressure Transmitters
Temperature Transmitters
http://www.autonics.com
Trusted Partner In Industrial Automation
HEADQUARTERS:
18, Bansong-ro 513beon-gil, Haeundae-gu, Busan,
South Korea, 48002
OVERSEAS SALES:
#402-303, Bucheon Techno Park, 655, Pyeongcheon-ro,
Wonmi-gu, Bucheon, Gyeonggi-do, South Korea, 14502
TEL: 82-32-610-2730 / FAX: 82-32-329-0728
E-mail: [email protected]
AEP-E-0121B