Ordering Information

This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
MP
5
-
❶ Size
S: DIN W 48 × H 48 mm
Y: DIN W 72 × H 36 mm
W: DIN W 96 × H 48 mm
❸ Output
Output
Main (comparative value) output Sub (display value) output
MP5S
N
Indicator
N
Indicator
1
NPN open collector quintuple
2
PNP open collector quintuple
MP5Y
3
Indicator
4
Indicator
5
Indicator
6
Relay triple (H, GO, L)
N
Indicator
A
Relay quintuple (HH, H, GO, L, LL)
1
Relay triple (H, GO, L)
2
NPN open collector quintuple
MP5W
4
NPN open collector quintuple
5
PNP open collector quintuple
8
NPN open collector quintuple
9
PNP open collector quintuple
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
• This dimensions shows the indicator. The connector (side length) is different according
to the output specification.
■ MP5S
□48
10
■ MP5Y
72
6
■ MP5W
96
MP5Y-
MP5Y-□N
MP5Y-□6
□1/2/3/4/5
A
10.5
14.5
15.3
B
-
-
-
■ Bracket
• MP5S
□49.5
30.5
60.3
■ Panel cut-out
A
B
C
❷ Power supply
2: 24 VACᜠ 50 / 60 Hz, 24 - 48 VDCᜡ
4: 100 - 240 VACᜠ 50 / 60 Hz
-
-
-
-
BCD Dynamic
PV transmission (current)
RS485 comm.
-
-
-
-
BCD Dynamic
PV transmission (current)
PV transmission (current)
RS485 comm.
RS485 comm.
90
89.5
A
6
89.5
MP5W-
MP5W-
MP5W-□N
□A/1
□2/4/5/8/9
-
-
-
10.5
10.5
14.5
• MP5Y / MP5W
73
A
B
C
MP5S
≥ 65
≥ 65
45
D
MP5Y
≥ 91
≥ 40
68
MP5W
≥ 116 ≥ 52
92
Manual
For proper use of the product, refer to the manuals and be sure to follow the safety
considerations in the manuals.
Download the manuals from the Autonics website.
Software
Download the installation file and the manuals from the Autonics website.
■ DAQMaster
It is the comprehensive device management program for Autonics' products, providing
parameter setting, monitoring and data management.
Cautions during Wiring
• Unit: mm, Use terminals of size specified below.
≥3.5
≤7.0
• Contact the manufacture for the socket and cable.
Model
MP5Y- □1 / 2 /
3 / 4 / 5
MP5W - □2 / 4 /
5 / 8 / 9
Connections
• Indicator model supports only power / input terminals.
• Connector or terminal block support varies by model. Refer to the cautions during
wiring.
• HOLD / RESET terminal function is different depending on the operation mode.
(F1 to F12: HOLD, F13 to F16: RESET)
■ MP5S
B
■ MP5Y
• Power / input terminal
1
2
3
INA
INB
HOLD / RESET
• 1: NPN open collector output
MAIN OUT (NPN OPEN COLLECTOR)
30 VDCᜡ 30 mA
HH
GO
2
4
1
3
COM
H
• 3: BCD Dynamic output
BCD OUT (NPN OPEN COLLECTOR)
30 VDCᜡ 30 mA
A
C
D0
2
4
1
3
COM
B
• 5: RS485 communication output
D
45
+ 0.5
+ 0.5
0
0
2
4
31.5
+ 0.7
+ 0.5
0
0
45
1
3
+ 0.8
+ 0.6
0
0
Specification
Hirose connector
HIF3BA-10PA-2.54DS
Applied connector socket
HIF3BA-10D-2.54R
Hirose connector
HIF3BA-20PA-2.54DS
Applied connector socket
HIF3BA-20D-2.54R
I / O cable (sold saparately) CO20-HP□-□
INA INB + 12 V 0 V HOLD / RESET
6
7
8
9
10
11
12
1
2
3
4
5
SOURCE
4
5
6
7
0 V
+ 12 V
SOURCE
• 2: PNP open collector output
MAIN OUT (PNP OPEN COLLECTOR)
30 VDCᜡ 30 mA
LL
HH
6
8
10
9
5
7
COM H
L
• 4: PV transmission output
DC 4 - 20 mA / DC 0 - 20 mA
Load 500 Ω Max.
D2
D4
6
8
10
2
9
5
7
1
D
D1
D3
• 6: relay triple output
RS485 B (-)
8
9
6
8
10
9
5
7
H
CONTACT OUT:
RS485 A (+)
250 VACᜠ 3 A, 30 VDCᜡ 3 A RESISTIVE LOAD
Manufacture
Hirose Electric
Hirose Electric
Autonics
GO
LL
2
4
6
8
10
9
1
3
5
7
L
(+)
4
6
8
10
9
3
5
7
(-)
10 11 12 13 14 15
GO
L