Autonics MX4W Series Product Manual - Page 3

Browse online or download pdf Product Manual for Measuring Instruments Autonics MX4W Series. Autonics MX4W Series 6 pages. Lcd multi panel meters

Autonics MX4W Series Product Manual

Mode Setting

[MODE] 2 sec
[MODE] 4 sec
RUN
[MODE]
[◀] + [▲] 3 sec
Zero adjustment
[MODE] + [◀] + [▲]
5 sec

Parameter Setting

• Some parameters are activated / deactivated depending on the model or setting of
other parameters. Refer to the description of each parameter.
• If any key is not entered for 60 sec in each parameter, it returns to RUN mode.
• After returning to RUN mode, press the [MODE] key within 2 sec, it returns to
previous parameter.
• [MODE] key: Saves current setting value and moves to the next parameter.
[◀] key: Checks fixed value / Changes setting digits.
[▲] key: Changes setting values.
■ Parameter 1 group
Parameter
Display Defaults Setting range
1-1
Input type
DC DC, -DC, AC
DCAC
50)0
Input range
-50)0
1-2
01)
IN-R
%000
-%000
Display
1-3
method
DISP
STND
Measurement
1-4
RMS AVG, RMS
method
IN-T
High-limit
display value
1-5
!000 0.100 to 9.999 %
gradient
SPAN
correction
Low-limit
display value
1-6
00 -99 to 99
deviation
ZERO
correction
Decimal
00)0
1-7
point
position
DOT
)000
1-8
High-limit scale
H-SC -
1-9
Low-limit scale
L-SC -
High-limit
display value
1-10
!000 0.100 to 9.999 %
gradient
SPAN
correction
Low-limit
display value
1-11
00 -99 to 99
deviation
ZERO
correction
02)
Decimal
00)0
1-12
point
position
DOT
03)
)000
High-limit
display value
1-13
!000 0.100 to 9.999
gradient
SPAN
correction
Exponent of
1-14
10-0 10-0: 10
SPAN
eSPN
High-limit
1-15
H-RG -
input value
Low-limit
1-16
L-RG -
input value
1-17 Display unit
dUNT
01)  When changing input range, the following parameters are reset.
- Parameter 1 group: display method, measurement method, decimal point position, high / low-limit scale, high-limit
display value gradient correction, exponent of span, high / low-limit input value, display unit
- Parameter 2 group: OUT1 / 2 output operation mode, OUT1 / 2 hysteresis
- Parameter 0 group: OUT1 / 2 high-limit output setting value, OUT1 / 2 low-limit output setting value, max. / min. peak value
02)  Low-limit display value deviation correction range is within -99 to 99 for D
03)  Display range is variable according to decimal point position.
Dot
Display range
Frequency measurement range
-9999 to 9999
1 to 1200 Hz
0
-999.9 to 999.9
0.1 to 999.9 Hz
)0
-99.99 to 99.99
0.10 to 99.99 Hz
)00
-9.999 to 9.999
0.100 to 9.999 Hz
)000
Parameter 1
[MODE] 3 sec
group
Parameter 2
[MODE] 3 sec
group
Parameter 0
[MODE] 3 sec
group
Auto
Reset
[MODE]
[MX4W-V-F□]
• Refer to Input Range and Display Range
[MX4W-A-F□]
• Refer to Input Range and Display Range
STND: standard, SCAL: scale,
FREQ: frequency*, PF: power factor**
[DC / AC voltage model]
0, 0.0, 0.00, 0.000
[DC / AC current model]
0, 0.0, 0.00, 0.000
Display value against max. measurement input*
Display value against min. measurement input*
[DC / AC voltage model]
0, 0.0, 0.00, 0.000
[DC / AC current model]
0, 0.0, 0.00, 0.000
, 10-1: 10
, 10-2: 10
, 10 1: 10
0
-1
-2
Max. value of input range
Min. value of input range
[DC / AC voltage model]
V, MV, OFF
V
[DC / AC current model]
A, MA, HZ, OFF
A
, D
digit regardless of decimal point position.
0
-1
■ Parameter 2 group
Parameter
OUT1
2-1
operation
mode
OUT2
2-2
operation
RUN
mode
OUT1
2-3
hysteresis
OUT2
2-4
hysteresis
Startup
2-5
compensation
time
Peak
2-6
monitoring
delay time
2-7
Display cycle
External
2-8
input
terminal
Display
condition
2-9
Lock
-
1-1 Input
■ Parameter 0 group
type:
DC, AC
1-1 Input
Parameter
type: -DC
1-1 Input
OUT1 high-
type:
0-1
limit output
DC, AC
setting value
1-1 Input
type: -DC
*1-1 Input
type: AC
**1-1 Input
type: ±DC
1-1 Input
type: AC
OUT1 low-
0-2
limit output
setting value
1-3
Display
method:
STND
1-3
OUT2 high-
Display
0-3
limit output
method:
setting value
SCAL
&
* 1-7
Decimal
point
position:
0.0, 0.00,
0.000
OUT2 low-
0-4
limit output
setting value
1-3
Display
method:
FREQ
1
1-3
Display
Display max.
0-5
method:
peak value
02)
PF
-
Display min.
0-6
peak value
01)  Setting range of OUT1 / 2 high / low-limit output setting value
1-1 input type +DC = -10 to 110 % of display range
1-1 input type -DC = -110 to 110 % of display range
1-1 input type AC = 0 to 110 % of display range
02)   Reset: Press [◀] + [▲] key for over 1 sec
Display Defaults Setting range
[Preset output model]
OFF, HIGH, LOW, HL, HL-G
OU!T
OFF
[Preset output model]
OFF, HIGH, LOW, HL, HL-G
OU@T
OFF
[DC / AC voltage model]
Within 10 % of max. display range, digit
0)1
[DC / AC current model]
HYs1
Within 10 % of max. display range, digit
)001
[DC / AC voltage model]
Within 10 % of max. display range, digit
0)1
[DC / AC current model]
HYs2
Within 10 % of max. display range, digit
)001
0)0 00.0 to 99.9 sec
STaT
00 S 00 to 30 sec
PEaK
)2 S 0.2 to 5.0 sec
DIsT
[Preset output model]
HOLD, ZERO
DI-T
HOLD
OFF: unlock,
LOC1: lock parameter 1,
LOC2: lock parameter 1, 2,
LOC
OFF
LOC3: lock parameter 0, 1 and 2
Display Defaults Setting range
[DC / AC voltage & preset output model]
50)0
OU!H
[DC / AC current & preset output model]
%000
[DC / AC voltage & preset output model]
00)0
[DC / AC current & preset output model]
)000
OU!L
[DC / AC voltage & preset output model]
-50)0
[DC / AC current & preset output model]
-%000
[DC / AC voltage & preset output model]
50)0
OU@H
[DC / AC current & preset output model]
%000
[DC / AC voltage & preset output model]
00)0
[DC / AC current & preset output model]
)000
OU@L
[DC / AC voltage & preset output model]
-50)0
[DC / AC current & preset output model]
-%000
Max. peak value in run mode
hPEK
)0
Min. peak value in run mode
02)
lPEK
)0
Display
condition
-
-
2-1 OUT1
operation
mode:
except
OFF
2-2 OUT2
operation
mode:
except
OFF
-
-
-
-
-
Display
01)
condition
2-1 OUT1
operation
mode:
HIGH, HL,
HL-G
1-1 Input
type:
DC, AC
&
2-1 OUT1
operation
mode:
LOW, HL,
HL-G
1-1 Input
type: -DC
&
2-1 OUT1
operation
mode:
LOW, HL,
HL-G
2-2 OUT2
operation
mode:
HIGH, HL,
HL-G
1-1 Input
type:
DC, AC
&
2-2 OUT2
operation
mode:
LOW, HL,
HL-G
1-1 Input
type: -DC
&
2-2 OUT2
operation
mode:
LOW, HL,
HL-G
2-1 OUT1
operation
mode:
except
OFF
or
2-2 OUT2
operation
mode:
except
OFF
&
2-6 Peak
monitor-
ing delay
time:
except
00