Autonics MX4W Series Product Manual - Page 4
Browse online or download pdf Product Manual for Measuring Instruments Autonics MX4W Series. Autonics MX4W Series 6 pages. Lcd multi panel meters
Input Range and Display Range
When the max. input value is over the 100 %, it may result in input terminal damage.
■ DC / AC voltage model (input type: DC)
Display range
Input range
Diaplay method: STND (fixed) Diaplay method: SCAL
0.0 - 500.0 VDCᜡ
0.0 to 500.0
0 - 500 VDCᜡ
0 to 500
0.0 - 200.0 VDCᜡ
0.0 to 200.0
0 - 200 VDCᜡ
0 to 200
0.00 - 50.00 VDCᜡ
0.00 to 50.00
0.0 - 50.0 VDCᜡ
0.0 to 50.0
0.00 - 20.00 VDCᜡ
0.00 to 20.00
0.0 - 20.0 VDCᜡ
0.0 to 20.0
0.000 - 5.000 VDCᜡ
0.000 to 5.000
0.00 - 5.00 VDCᜡ
0.00 to 5.00
1.000 - 5.000 VDCᜡ
1.000 to 5.000
1.00 - 5.00 VDCᜡ
1.00 to 5.00
0.000 - 2.000 VDCᜡ
0.000 to 2.000
0.00 - 2.00 VDCᜡ
0.00 to 2.00
0.0 - 500.0 mVDCᜡ
0.0 to 500.0
0 - 500 mVDCᜡ
0 to 500
0.0 - 200.0 mVDCᜡ
0.0 to 200.0
0 - 200 mVDCᜡ
0 to 200
0.00 - 50.00 mVDCᜡ
0.00 to 50.00
0.0 - 50.0 mVDCᜡ
0.0 to 50.0
01) Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
■ DC / AC voltage model (input type: -DC)
Display range
Input range
Diaplay method: STND (fixed) Diaplay method: SCAL
-500.0 - 500.0 VDCᜡ
-500.0 to 500.0
-500 - 500 VDCᜡ
-500 to 500
-200.0 - 200.0 VDCᜡ
-200.0 to 200.0
-200 - 200 VDCᜡ
-200 to 200
-50.00 - 50.00 VDCᜡ
-50.00 to 50.00
-50.0 - 50.0 VDCᜡ
-50.0 to 50.0
-20.00 - 20.00 VDCᜡ
-20.00 to 20.00
-20.0 - 20.0 VDCᜡ
-20.0 to 20.0
-5.000 - 5.000 VDCᜡ
-5.000 to 5.000
-5.00 - 5.00 VDCᜡ
-5.00 to 5.00
-2.000 - 2.000 VDCᜡ
-2.000 to 2.000
-2.00 - 2.00 VDCᜡ
-2.00 to 2.00
-500.0 - 500.0 mVDCᜡ -500.0 to 500.0
-500 - 500 mVDCᜡ
-500 to 500
-200.0 - 200.0 mVDCᜡ -200.0 to 200.0
-200 - 200 mVDCᜡ
-200 to 200
-50.00 - 50.00 mVDCᜡ -50.00 to 50.00
-50.0 - 50.0 mVDCᜡ
-50.0 to 50.0
01) Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
■ DC / AC voltage model (input type: AC)
Display range
Input range
Diaplay method: STND (fixed) Diaplay method: SCAL
0.0 - 500.0 VACᜠ
0.0 to 500.0
0 - 500 VACᜠ
0 to 500
0.0 - 200.0 VACᜠ
0.0 to 200.0
0 - 200 VACᜠ
0 to 200
0.0 - 110.0 VACᜠ
0.0 to 110.0
0 - 110 VACᜠ
0 to 110
0.00 - 50.00 VACᜠ
0.00 to 50.00
0.0 - 50.0 VACᜠ
0.0 to 50.0
0.00 - 20.00 VACᜠ
0.00 to 20.00
0.0 - 20.0 VACᜠ
0.0 to 20.0
0.000 - 5.000 VACᜠ
0.000 to 5.000
0.00 - 5.00 VACᜠ
0.00 to 5.00
0.000 - 2.000 VACᜠ
0.000 to 2.000
0.00 - 2.00 VACᜠ
0.00 to 2.00
0.0 - 500.0 mVACᜠ
0.0 to 500.0
0 - 500 mVACᜠ
0 to 500
0.0 - 200.0 mVACᜠ
0.0 to 200.0
0 - 200 mVACᜠ
0 to 200
0.00 - 50.00 mVACᜠ
0.00 to 50.00
0.0 - 50.0 mVACᜠ
0.0 to 50.0
01) Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
01)
50)0
500
20)0
200
5)00
5)0
2)00
Decimals
Display range
2)0
0 -9999 to 9999
%000
)0 -999.9 to 999.9
%00
)00 -99.99 to 99.99
1-5A
)000 -9.999 to 9.999
1-5B
@000
@00
50)0
500
20)0
200
5)00
5)0
01)
-50)0
-500
-20)0
-200
-5)00
-5)0
Decimals
Display range
-2)00
0 -9999 to 9999
-2)0
)0 -999.9 to 999.9
-%000
)00 -99.99 to 99.99
-%00
)000 -9.999 to 9.999
-@000
-@00
-50)0
-500
-20)0
-200
-5)00
-5)0
01)
50)0
500
20)0
200
11)0
110
5)00
Decimals
Display range
5)0
0 -9999 to 9999
2)00
)0 -999.9 to 999.9
2)0
)00 -99.99 to 99.99
%000
)000 -9.999 to 9.999
%00
@000
@00
50)0
500
20)0
200
5)00
5)0
■ DC / AC current model (input type: DC)
Input range
0.000 - 5.000 A
Input
0.00 - 5.00 A
impedance
0.000 - 2.000 A
0.00 - 2.00 A
0.0 - 500.0 mA
0 - 500 mA
4.062 MΩ
0.0 - 200.0 mA
0 - 200 mA
0.00 - 50.00 mA
0.0 - 50.0 mA
0.00 - 20.00 mA
0.0 - 20.0 mA
4.00 - 20.00 mA
162 kΩ
4.0 - 20.0 mA
0.000 - 5.000 mA
0.00 - 5.00 mA
0.000 - 2.000 mA
0.00 - 2.00 mA
01) Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
4 kΩ
■ DC / AC current model (input type: -DC)
Input range
-5.000 - 5.000 A
-5.00 - 5.00 A
-2.000 - 2.000 A
Input
-2.00 - 2.00 A
impedance
-500.0 - 500.0 mA
-500 - 500 mA
-200.0 - 200.0 mA
4.062 MΩ
-200 - 200 mA
-50.00 - 50.00 mA
-50.0 - 50.0 mA
-20.00 - 20.00 mA
-20.0 - 20.0 mA
-5.000 - 5.000 mA
162 kΩ
-5.00 - 5.00 mA
-2.000 - 2.000 mA
-2.00 - 2.00 mA
01) Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
■ DC / AC current model (input type: AC)
4 kΩ
Input range
0.000 - 5.000 A
0.00 - 5.00 A
0.000 - 2.000 A
0.00 - 2.00 A
0.0 - 500.0 mA
Input
0 - 500 mA
impedance
0.0 - 200.0 mA
0 - 200 mA
0.00 - 50.00 mA
0.0 - 50.0 mA
4.062 MΩ
0.00 - 20.00 mA
0.0 - 20.0 mA
0.000 - 5.000 mA
0.00 - 5.00 mA
0.000 - 2.000 mA
0.00 - 2.00 mA
01) Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
162 kΩ
range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
4 kΩ
Display range
Diaplay method: STND (fixed) Diaplay method: SCAL
0.000 to 5.000
%000
0.00 to 5.00
%00
0.000 to 2.000
@000
0.00 to 2.00
@00
0.0 to 500.0
50)0
0 to 500
500
0.0 to 200.0
Decimals
20)0
0 to 200
200
0.00 to 50.00
)0 -999.9 to 999.9
5)00
0.0 to 50.0
)00 -99.99 to 99.99
5)0
0.00 to 20.00
)000 -9.999 to 9.999
2)00
0.0 to 20.0
2)0
4.00 to 20.00
4A20
4.0 to 20.0
4B20
0.000 to 5.000
%000
0.00 to 5.00
%00
0.000 to 2.000
@000
0.00 to 2.00
@00
Display range
Diaplay method: STND (fixed) Diaplay method: SCAL
-5.000 to 5.000
-%000
-5.00 to 5.00
-%00
-2.000 to 2.000
-@000
-2.00 to 2.00
-@00
-500.0 to 500.0
-50)0
-500 to 500
Decimals
-500
-200.0 to 200.0
-20)0
-200 to 200
)0 -999.9 to 999.9
-200
-50.00 to 50.00
)00 -99.99 to 99.99
-5)00
-50.0 to 50.0
)000 -9.999 to 9.999
-5)0
-20.00 to 20.00
-2)00
-20.0 to 20.0
-2)0
-5.000 to 5.000
-%000
-5.00 to 5.00
-%00
-2.000 to 2.000
-@000
-2.00 to 2.00
-@00
Display range
Diaplay method: STND (fixed) Diaplay method: SCAL
0.000 to 5.000
%000
0.00 to 5.00
%00
0.000 to 2.000
@000
0.00 to 2.00
@00
0.0 to 500.0
50)0
0 to 500
Decimals
500
0.0 to 200.0
20)0
0 to 200
)0 -999.9 to 999.9
200
0.00 to 50.00
)00 -99.99 to 99.99
5)00
0.0 to 50.0
)000 -9.999 to 9.999
5)0
0.00 to 20.00
2)00
0.0 to 20.0
2)0
0.000 to 5.000
%000
0.00 to 5.00
%00
0.000 to 2.000
@000
0.00 to 2.00
@00
Input
impedance
01)
0.02 Ω
Display range
0.87 Ω
0 -9999 to 9999
21.87 Ω
Input
impedance
01)
0.02 Ω
Display range
0 -9999 to 9999
0.87 Ω
21.87 Ω
Input
impedance
01)
0.02 Ω
Display range
0 -9999 to 9999
0.87 Ω
21.87 Ω