Routine Maintenance
Wipe clean the inside of the cabinet once a week using a damp cloth. It is
recommended that the condenser is cleaned free of dirt and grime
approximately every 6 months. The condenser is accessed from the rear of the
machine and is the silver coloured object with metal 'fins' situated under the fan
on the refrigeration components deck. Failure to keep the condenser clean will
reduce the refrigeration performance of the unit.
Repairs
Warning: Ensure unit is switched off at the mains before attempting the
following maintenance and repair procedures.
Lamp Replacement:
"
Open the front door and remove the lamp cover. This is achieved by
slightly compressing the cover and lowering from its holder.
"
Twist the lamp from its socket and remove from the cabinet.
"
Reverse the procedure to fit new lamp.
Starter replacement:
"
Open the front door.
"
Starter is located at top right hand corner of inner cabinet. Twist
anti-clockwise to remove.
"
Twist new starter clockwise into position.
End of life disposal
This unit contains fluorinated greenhouse gas HFC-134a regulated by the
Kyoto protocol, the warming potential of which is 1300, and therefore must be
disposed of responsibly.