Q & A
How can I tell if my CO2 reading is accurate? You can check
the calibration of the CO2 sensor by placing the sensor outdoors
for 30 minutes. It should read close to 380 PPM. *See the HOW
TO calibrate section.
When I turn on power, the unit says CO2 heat? This is normal,
it takes 5 minutes for the sensor to warm up.
SEn? The remote probe is not
Why is the display reading
Err
connected and/or communicating with the controller. Check the
quick-connect cable and that the remote probe is getting power.
*Contact the factory for more info.
What if the of the small green Error LEDs are on? The CO2
sensor or CO2 device is not acting correctly. Refer to the Error
LEDs sections to diagnose the problem.
Why isn't the CO2 outlet turning on? Verify the correct CO2
mode has been selected and/or verify the photocell daytime
green led is turned ON.
What if there is no power? Reset the power switch (circuit
breaker).