Basic Functions
1. A special combination of buttons presses is used to start the heater from a
remote control key. Firstly press "Lamp" button on the key to switch on car
lighting. Then press "Lock" button twice within 30 seconds, while lighting
is on. Every "Lock" button pressing is confirmed with direction indicators
flashing.
2. To stop the heater with a remote control key, switch on and then switch off
car lighting twice. Intervals between "Lamp" button presses should not
exceed 20 seconds.
3. It is possible remotely disable heater timers, programmed in the CIP. Use
remote control key to send stop command when the heater is idle. Starting
the heater any way or turning ignition to "on" position enables CIP timers
again.
Additional Functions
By default the module adjusted to perform only basic functions, such as start
and stop of the heater by using remote control key. To switch on additional
functions such as flashing with direction indicators in rearview mirrors, etc. enter
the module into Setup mode and activate corresponding setup item (see settings
table 1).
The buttons of the left-hand stalk switch and the brakes pedal are used to
enter Setup mode and to change the settings. It is necessary to stop the engine and
the heater before. Switch the ignition on (turn the key to the position II), then press
and hold the brakes pedal. Rotate the thumbwheel some steps to select blank
display in the CIP. Then press and hold for at least 5 seconds "Read" button ("OK"
button in some cars), while module's LED flashes once a second. Both direction
indicators in the CIP confirm entering setup mode with 2 flashes. Release the
brakes pedal and "Read/OK" button finally.
Each setup item in the settings table is a 3-digit code. To enter a digit of a
code, shortly press "RESET" button so much times, as corresponds to a digit. The
LED and the direction indicators symbols in the CIP confirm each button press: the
LED briefly goes off, the left direction indicator flashes one time when the first or
the third digit of code is entered, the right direction indicator - when the second
digit of code is entered. To complete a digit entering, press and release "Read/OK"
button. The CIP confirms it with one flash of both direction indicators
simultaneously. When all three digits are entered, the module checks the code for
validity and confirms it with direction indicators flashing. Both direction indicators
flash twice simultaneously in case of valid code and flash twice alternately in case
of invalid code.
4