Dynatech STAR Instructions For Use And Maintenance Manual - Page 16
Browse online or download pdf Instructions For Use And Maintenance Manual for Industrial Equipment Dynatech STAR. Dynatech STAR 18 pages. Overspeed governor
INSTRUCTIONS: Star Cod: DYN 09.1.19
Date: 14/12/2022 Revision: 19
maintenance staff, although they should be more frequent in the case of an especially corrosive environment.
Dynatech will not be responsible for any problem or accident caused by not observing the prescriptions and
recommendations described, both in these instructions and in the EEC Type-examination certificate documents
9.1 STORAGE AND SERVICE LIFE
The overspeed governor must be stored in a cool, dry place. It must be protected from excessive light and never be
exposed to the open air.
Storage temperature: 5 - 40ºC.
Storage Humidity: 15 - 85% without condensation
Overspeed governor packages should be clean and dry so that they can be clearly identified.
Constantly leaning an unbalanced load on packages, which may cause bending, or the accumulation of products
stacked on top of each other is not allowed. When placing products or product packages on top of each other, the
storage height should correspond to the packages' load and stability.
If the established criteria of this manual are observed, the overspeed governor's service life is set by the wear of his
main pulley groove, which depends on the installation duty cycle. When estimating the element's service life, the
effects of grease, dust or dirt due to the shaft's condition or to environmental conditions differing from those stated in
this manual, were not taken into consideration.
10 INSTALLATION DRAWINGS
The following drawings may be of help when adapting and installing the STAR and STAR PLUS overspeed governor
to the sling.
Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer
area in Dynatech's website in order to consult the full manual; http://customers.dynatech-elevation.com/
14