2hp ADSR Manual - Page 6

Browse online or download pdf Manual for Control Unit 2hp ADSR. 2hp ADSR 7 pages.

2hp ADSR Manual
General Functions Overview
1. GATE:
Gate input
An envelope will emit from OUT when a gate signal is received at the GATE input
Threshold: 2.5V
2. RANGE:
Toggle that will switch between two ranges
If the toggle is up, the slow range will be selected
If the toggle is down, the fast range will be selected
Slow Range: 0.54ms – 5 sec per stage
Fast Range: 5ms – 30 sec per stage
3. LED:
LED indication of the envelope emitted from OUT
4. OUT:
Envelope output
Range: 0V – 10V
5. ATTACK:
Sets the attack time of the envelope
If the knob is far left, the attack time will be as fast as possible based on the currently
selected range
If the knob is far right, the attack time will be as slow as possible based on the
currently selected range
6