8.
Line up the new replacement I/O termination board with the screw holes and reattach it
using the eight screws. Torque screws to 4 to 6 in-lbs. (0.5 to 0.7 N m).
9.
If present, place the optional 8-channel expansion I/O board on the posts, and carefully line it
up to avoid bending pins. Gently press the expansion I/O board down onto the I/O
termination board. Reattach the 8-channel expansion I/O board to the I/O termination board
using the four screws you removed in step 5. Torque screws to 1 to 2 in-lbs (0.1 to 0.2 N m).
10.
Take the CPU enclosure (with the HMI module attached) and line up the CPU enclosure's
captive fastening screws with their matching holes on the I/O assembly. Press the enclosure
screws onto the holes and hold it there while tightening each of the captive fastening
screws. Torque screws to 7 to 9 in-lbs. (0.8 to 1.0 N m).
11.
Connect the intermediate cable to the sensor module and make sure it has clearance.