Section 363-765-105
C. INSTALLATION AND TEST
5. Unpacking
5.1
Upon receipt of the equipment:
1
Unpack each container and visually inspect it for signs of damage. If the equipment has been
damaged in transit, immediately report the extent of damage to the transportation company and
to PairGain. Order replacement equipment if necessary.
2
Check the contents against the packing list to ensure complete and accurate shipment. If the
shipment is short or irregular, contact PairGain as described in Section 12.3. If you must store
the equipment for a prolonged period, store the equipment in its original container.
6. Installation Requirements
6.1
Prior to installing the FRE-765, be aware of these installation requirements or conditions shown in
Table 12.
Requirement
Environmental
Mounting
Power
HDSL Lines
Subscriber Lines
List 5
List 5A
Metallic Bypass Pair
Doubler
Cable Entry
Protectors
Page 10
June 2, 1997
Table 12. Installation Requirements
Description
The FRE-765 can operate in an outside plant environment. It can operate in a temperature
range of -40°F to +150°F (-40°C to +65°C) and a humidity range of 5% to 95% (non-
condensing).
The FRE-765 has external mounting flanges with a clearance hole for a 3/8-inch bolt for
pole or wall mounting. The customer must provide the appropriate mounting hardware.
When mounting to a pole using the Pole Mounting Kit (PN 150-1397-00), ensure that the
pole mounting bracket and FRE-765 are fully installed before installing cabling.
The FRE-765 gets power from the HDSL lines connected to the COT shelf in the
Central Office (CO). When a doubler is installed between the PG-Flex COT Shelf and RT
enclosure, two additional power pairs are required from the COT shelf and RT enclosure.
Two HDSL pairs are terminated in the FRE-765.
Provides three 25-pair Amphenol connectors (male) for subscriber line terminations.
Provides AMP Quiet Front insulation displacement connections for subscriber terminations.
The metallic bypass pair for subscriber line testing is terminated in the FRE-765. Do not
connect the bypass pairs between PG-Flex systems or to other DLC systems.
When using a doubler, add two AMP Quiet Front terminals to the FRE-765 to terminate
the auxiliary power pairs from the COT. Order the Quiet Front kit (PN 150-1399-25) which
contains two Quiet Front terminations, four jumpers, and a tool for inserting the jumpers
into the insulation displacement barrels.
Knockouts are located on the bottom of the FRE-765 and accept ¾-, 1-, 1½-, and 2-inch
fittings. Install grommet (provided with FRE-765), conduit, or cable strain relief fittings
prior to wiring the FRE-765.
Install 5-pin protectors (short housing) for each working subscriber circuit in the FRE-765
List 5A. These may be carbon, gas tube, or solid state protectors, depending on local
practice.