Dea ghost 200 Operating Instructions And Warnings - Page 6

Browse online or download pdf Operating Instructions And Warnings for Gate Opener Dea ghost 200. Dea ghost 200 17 pages. Underground electro-mechanical operator for swing gates
Also for Dea ghost 200: Operating Instructions Manual (16 pages)

Dea ghost 200 Operating Instructions And Warnings
"EXAMPLE OF TYPICAL INSTALLATION" picture
1
2
3
4
5
Type of control
Person-present control
Pulse control with the gate in
sight
Pulse control with the gate
not in sight
Automatic control
(i.e. control with
timed closing)
Remember that anyone who sells and/or motorises doors/gates becomes the manufacturer of the automatic door/gate
machine and must therefore prepare and preserve a technical folder that contains the following documents (see Machinery
Directive Enclosure V):
• Assembly drawing of the automatic door/gate;
• Electrical connection and control circuit wiring diagram;
• Risk analysis including: a list of the essential safety requirements provided in Machinery Directive Enclosure I; a list of the risks
posed by the door/gate and the description of the solutions adopted.
• Keep these operating instructions in a safe place together with the instructions for all the other components;
• Prepare these operating instructions and general safety warnings (by filling in these operating instructions) and hand a copy
to the final user;
• Fill in the maintenance handbook and hand a copy to the final user;
• Draft the CE declaration of conformity and hand a copy to the final user;
• Fill in the complete CE label or plate and apply it to the door/gate.
Note: The technical folder must be preserved for inspection by the competent national authorities for at least ten years from
the date of construction of the automatic door/gate.
Operating instructions and warnings
6
7
8
9
"OPERATING CONTROL" table
Informed users
(private areas)
Pushbutton control
Pushbutton control with key
Force limitation
or
presence detectors
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
RESPONSIBILITIES OF THE INSTALLER
10
Type of use
Informed users
(public areas)
The person-present control is
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
GH OS T 200
Pos.
Description
1
102 Lux key switch
2
Remote-control
3
Pilly 60 column
4
Safety edge
5
Electric lock
6
FLIC/rad digital
keypad
7
104 Lux series
photocells
8
GHOST
9
Control board
10
Lumy flashing light
Uninformed users
not possible
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
11