Adexa 6G-TRH60 Installation And Operation Instruction Manual - Page 10
Browse online or download pdf Installation And Operation Instruction Manual for Grill Adexa 6G-TRH60. Adexa 6G-TRH60 20 pages. Gas lava rock grill
Installation
14.
Turn over gas LAVA ROCK GRILL , and needle type pressure joint screw arbor (Fig.1), then slip rubber tube
of pressure gauge over needle type pressure joint;
15.
Start the equipment in accordance with the instructions, measuring gas supply pressure (dynamic pressure)
in the work state;
16.
Access to the equipment if measured data within the limits of Table 1, otherwise, you will need to adjust
gas pressure regulating valve or contact gas supplier to bargain;
17.
The gas inlet is located on the lower rear of the LAVA ROCK GRILL . Codes require that a gas shutoff valve
be
18.
installed in the gas line ahead of the LAVA ROCK GRILL.
19.
Make sure the pipes are clean and free of obstructions, dirt, and piping compound.
NOTE: LP Gas cylinder shall be purchased from local site and matched with local national requirements, Supply
gas type and pressure required for this appliance was shown on rating label , 9kg to 23kg LP gas
cylinder shall be used for current gas LAVA ROCK GRILL. maximal external dimensions (regulator
included) shall not be more than dia. 500mm X900mm.
LP Gas cylinder
1. LP Gas cylinder shall be Kept with 1meters Min space from gas LAVA ROCK GRILL. gas cylinder shall be
located outside the appliance in well ventilation space, Gas cylinder shall never be moved during operation
period, it shall be fixed with rigid support.
2. If gas cylinder was inserted with compartment, effective ventilation is provided by openings compartment
base and upper side areas. The total area of the openings in the upper part being at least 1/100th of the
floor area of the compartment and that of the openings at the base being at least 1/50th of the floor area
of the compartment;
3. The cylinder support has sufficient mechanical strength to resist permanent deformation under the load
weight of a full cylinder; an arrangement with the cylinder resting directly on the ground is not allowed
4. The cylinder fitted with a regulator can be easily installed or removed from the compartment, the cylinder
can be easily installed in a vertical position with the valve and regulator upper most; the cylinder valve is
accessible and remain easy to manipulate when the cylinder is in place;
5. no internal communication means or conduits shall exist between the cylinder compartment and
parts of the appliance where burners are located, It shall not be possible to block or obstruct the ventilation
openings of the compartment accidentally, when the gas cylinder is placed in position.
6. The compartment shall be designed and constructed in such a way as to ensure that a permanent supply of
fresh air is ensured and there is no accumulation of un-burnt gases.
Fig.1
8