Adexa 6G-TRH60 Installation And Operation Instruction Manual - Page 9

Browse online or download pdf Installation And Operation Instruction Manual for Grill Adexa 6G-TRH60. Adexa 6G-TRH60 20 pages. Gas lava rock grill

Installation
LP Gas hose connection
NOTE: Manual Isolation Valve
and flexible hose were not include with current product. Purchase them in your local
site. The gas type and gas pressure shall be matched with gas rating label in product
body. Any issue pls. contact the Dealer of this appliance.
NOTE: It is important that adequately sized piping runs directly to the connection joint on the appliance
with as few tees and elbows as possible to give maximum supply volume
NOTE: Ensure the regulator is converted to the correct gas type that the appliance will operate on. The
regulator outlet pressure is fixed ex-factory for the gas type .
NOTE: the appliance should be used on a table , the table material should be Non
Combustible and the height should be not exceed 800mm。
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs so that
the unit is level and at the correct height.
3.
Connect the gas supply to the appliance through the regulator. (refer to the picture of "Install the
Regulator. A suitable jointing compound which resists the breakdown action of propane must be
used on every gas line connection, unless compression fittings are used.
4.
Check all gas connections for leakages.
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
5.
Check that the gas operating pressure.
NOTE: The operating pressure to be measured at the manifold test point and with 2 burners operating at the
'High Flame' setting.
6.
Turn off the mains gas supply and bleed the gas out of the appliance gas lines.
7.
Turn on the gas supply and the appliance.
8.
Verify that the operating pressure remains correct.
9.
All gas supply connections and any pipe joint compound must be resistant to the action of nature gas and
propane gases.
10.
The gas inlet is located on the lower rear of the LAVA ROCK GRILL . Codes require that a gas shutoff valve
be
11.
installed in the gas line ahead of the LAVA ROCK GRILL.
12.
Make sure the pipes are clean and free of obstructions, dirt, and piping compound.
13.
After installing completely, you should check gas supply pressure. Use a pressure gauge which is equipped
with liquid (such as U-type pressure gauge, the minimum value is 0.1mbar) or a digital pressure gauge to
test. Steps are as following:
,
Gas hose adaptor, seal gasket, gas pipe, LP or nature regulator
WARNING
7
Nature gas connection
: