AirFiltronix ES-7000 Assembly And Installation Instructions - Page 2
Browse online or download pdf Assembly And Installation Instructions for Air Cleaner AirFiltronix ES-7000. AirFiltronix ES-7000 4 pages. Mini-containment hood
1. Unpack the enclosure and check for shipping damage. Place on table or portable cart approximately 32-34" high.
(see Figure 1).
2. Unpack the ES7000 blower unit.
Figure 1
3. Unsnap latches on either side of the blower enclosure ( see figure 2) and lift the blower unit off its base (see figure 3).
Remove the line cord packaged inside the enclosure and loosen the wingnuts on either side of the compression bar
until the bar can be lifted approximately 4-5 inches above the filter frame (see figure 4). Place blower base on top of
enclosure allowing the 8" opening in underside of blower base to sit over the 8" collar with closed cell
gasket on top of the enclosure.
Figure 3
Check that the blower base sits snugly on top of the gasket seals to avoid any possibility of leakage (see figure 5). Unpack
the filters supplied with the unit (see appendix A) and lift the compression bar. Install filter(s) into the filter frame with its
gasketed side down (see figure 6).
Figure 5
ES-7000 Enclosure Installation Instructions
Figure 2
Figure 4
Figure 6