6) INSTRUCTIONS FOR USE:
Before accessing the elevator shaft, elevator pit in the case of low pits, or the elevator roof in the case of
systems with reduced headroom, the maintenance technician must first open the door of the lowest floor
and activate the vertical buffer support. The mechanism is activated and deactivated from floor level without
the need to enter the pit.
Buffer Support activation: This is done by pulling on the green cable. The tube drops down to active
position and the electrical contact only allows operation during elevator review.
Buffer Support deactivation: To deactivate the buffer support, pull on the red cable. As it rises into
place there is a sound indicating that the trigger has blocked the mechanism, it has been deactivated
and the manoeuvre can return to normal operation.
MANUAL FOR INSTALLATION AND USE
DNP16-01. PIVOTING BUFFER SUPPORT
BRAND PRODUCT
If the mechanism does not block correctly
the trigger can be adjusted using the cable
tightener. Turn it to adjust the trigger
position by increasing and reducing its
length and tension.