Centrometal EKO-CUP V3 Technical Instructions - Page 16

Browse online or download pdf Technical Instructions for Industrial Equipment Centrometal EKO-CUP V3. Centrometal EKO-CUP V3 20 pages.

Burner adjustment and mounting

10.1. BURNER ADJUSTMENT

Burner must be adjusted according to the technical instructions for the oil / gas burner.
10.2.

BURNER MOUNTING

Burner mounting
is used if the factory made opening on the boiler door is too large for the chosen
burner. In that case it is necessary to make an appropriate opening for the passage of the burner tube
and to cut the existing mineral wool isolation layer according to the mentioned opening. If it is
necessary, make attach holes for the burner.
Figure 4: Burner mounting on the boiler EKO-CUP V3
Boiler door isolation
ATTENTION !!
If the factory made opening on the boiler door is too large for the chosen burner, it is necessary to make
an appropriate opening for burner tube passage on the blind panel. The existing isolation mineral wool
layer have to be cut to be consistent with that opening. For the burner connection use the existing
holes or if it is necessary make new attach holes for the burner. If after the boiler montage, the gap
between the burner tube and the mineral wool isolation of the boiler door still exist, it is necessary to fill
the gap with pieces of the mineral wool and the braid ( which is delivered with the boiler ) so that the gap
becomes closed (Figure 4).
16
Mineral wool
Isolation panel
Blind panel
Gap which must
be closed
Burner tube
Technical instructions EKO-CUP V3