Gandy 36H12 Operator's Manual - Page 7
Browse online or download pdf Operator's Manual for Spreader Gandy 36H12. Gandy 36H12 10 pages. 24” & 36” spreaders
Also for Gandy 36H12: Operator's Manual (8 pages), Operator's Manual (8 pages)
Bottom Disassembly Instructions:
Occasionally it will be necessary to disassemble the stainless bottom for cleaning.
Some materials will build up in between the slide and the bottom especially when atmospheric humidity is high.
1. Remove the 5/16" wing nut, washer and cam gauge from bottom assembly.
Diagram A
2. Measure the distance from the edge of the bottom to the edge of the rear hanger and write that down.
See Diagram B. You will use this dimension to reassemble the bottom.
Diagram B
3. Remove the 3/16" flange nuts and nylon washers from the rear hanger.
Note: The 36" bottom has 4 nuts and washers. The 24" bottom has 2.
Diagram C
~5 ~
OPP-36-24-A1
OPP-36-24-A1
OPP-36-24-A1