3. Use  a  drill  to  drill  two  holes  with  the 
depth of 30mm and diameter of 6mm to 
6.5mm on the wall. 
 
Wall 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Note:
Avoid embedded wires in the wall during drilling! 
5. Bracket. 
Normal Installation: Align holes on the bracket with installation holes on the wall 
and the 86 x 86mm wall‐mounted junction box and use the Phillips screwdriver 
to tighten the screws clockwise to fasten the bracket. 
Waterproof Installation: The waterproof installation process is basically the same 
as the normal installation process. You need to fasten the bracket and waterproof 
hood together, for detail, see figure below. After the waterproof installation is 
completed, apply enough silicone rubber along the gap between the edge of the 
waterproof hood and the wall (left, top and right). Silicone rubber must be 
continuous. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(without waterproof hood) 
 
 
4. Embed expansion bolts inside the 
two installation holes on the wall. 
 
 
 
 
 
 
 
 
 
 
 
(with waterproof hood) 
Wall