deconta ME 12 Original Instruction Manual - Page 12

Browse online or download pdf Original Instruction Manual for Vacuum Cleaner deconta ME 12. deconta ME 12 16 pages. Mobile deduster

deconta ME 12 Original Instruction Manual
Instruction manual
Mobile Deduster ME 12
Measured negative pressure
Set value in automatic operation
Fan performance in %
Operating mode (AUTO or MANUAL)
Manual operation:
In manual operation, the „+" and „-" keys are used to set the fan performance. The
display show the performance value in „%" and the measured negative pressure.
Automatic operation:
In automatic mode, the set point in Pascal for the negative pressure is preset with the
keys „+" and „-„ (display set value in automatic mode). By comparing the entered set
point value with the permanently measured current actual value (measured negative
pressure), the speed of the fan is automatically adapted, that is, the fan moves
automatically „up" and „down".
Important:
In the event of power failure, the control saves the last set values, restarts automatically
after damage elimination and restores the saved data.
Version 1
Seite 12