6.2. Option Dust bunker with filling level control and emptying via suction port
A full bunker is indicated by two signal lights on the control unit.
When the bunker is full, the alarm socket is supplied with power. An external signal light
or signal horn can be connected to this alarm socket.
For emptying the bunker, there are 2 suction connections on the unit.
Switch off Fan and Cleaning function of the mobile dust extractor!
Connect the suitable vacuum cleaner to the suction connection
Open shut-off valve
The Bunker can now be vacuumed
Please note!
After emptying, the shut-off valve must be closed again.