5.
Remove the spray tube and water tank filter to examine if calcium or mineral deposits remain, then use a paper clip to remove
any remaining build-up and rinse using vinegar and water.
6.
Slide metal cover back onto the tube and replace water tank filter inside water tank
7.
Pour 1 Cup of white vinegar onto the generator surface and let soak for 15 minutes
8.
Rinse the generator surface and scrape off any remaining calcium or mineral build-up
9.
Wipe generator clean with a damp cloth and reassemble unit and spray tube
If excessive mineral deposits remain after cleaning, follow the directions below:
1.
Treat generator surface with a delimer solution. Follow all instructions and safety precaution as stipulated by the
delimer's manufacturer. If using a chemical cleaner, make sure it is safe to use on the generator surface.
2.
Remove delimer solution from generator with a sponge or dry towel. Rinse generator with clean water.
NOTE: Some calcium/mineral build-up is required on the generator surface for proper steaming. If all build-up
is removed during cleaning, add distilled water to surface, and allow it to boil off. Repeat as needed until the
generator surface is thinly coated in calcium/mineral deposits.
NOTE: It may be necessary to season the generator surface with lime if using soft water. Seasoning creates a thin
coating of calcium/mineral deposits on the generator to ensure proper steaming.
To season, mix 3/4 oz. baking soda, 3/4 oz. lime, and 1 qt. water. Pour 1/4" deep onto hot generator surface. Allow
the mixture to boil off. Remove any loose powder that remains.
3.
Plug power cord into electrical outlet.
4.
Flip the on/off switch to the 'on' position. Allow steamer to preheat for 30 minutes.
5.
Press and release steam button several times to purge delimer residue from generator.
6.
Flip on/off switch to the 'off' position. Reinstall parts and accessories.
8