caution: Cleaved or broken glass fibers are very sharp and can pierce the skin easily.
Do not let these pieces of fiber stick to your clothing or drop in the work area where they
can cause injury later. Use tweezers to pick up cleaved or broken pieces of glass fibers
and place them on a loop of tape kept for that purpose alone. Good housekeeping is
very important.
2.
SPLICe CaSSeTTe (CCH-CS) INSTaLLaTIoN — TIGHT BUFFeR oR LooSe
TUBe FIBeR
2.1. Fiber Routing
3
STANDARD RECOMMENDED PROCEDURE 003-895 | ISSUE 1 | OctOber 2011 | PAGE 2 OF 11
1
27 inches
2
4
TPA-3928
TPA-3929